1
SPECIFICATIONS
Display:
¼” digits, 3-line LCD display
Range:
9 hrs, 59 min, 59 sec, 99/100
Resolution: 1/100 sec
Accuracy:
0.001%
Features:
Continuous Timing, Lap/Split Timing, Countdown/Count up Timing,
Speed Timing, Stroke Timing, Pacer Timing, Time/Calendar
display, Daily Alarm
CONTROLS
Listed below are the unit’s buttons along with their function in the various
stopwatch modes.
START/STOP Button
1.
Stopwatch – starts and stops timer
2.
Speed – starts and stops speed function
3.
Stroke – starts and stops stroke function
4.
Time/Calendar – advance digits when setting time of day
5.
Alarm – silences alarm
6.
Pacer – starts and stops pacer function
7.
Timer – starts and stops timer function
RESET/LAP SPLIT Button
1.
Stopwatch – with timer running records a lap/split time. With timer stopped
resets display to zero
2.
Speed – when in value setting mode advances through fields in order to set
values
3.
Stroke – resets stroke count to 2400
4.
Time/Calendar – switches hourly reading from 12- or 24-hour setting
5.
Alarm – enable/disable alarm
6.
Pacer – sets pacer value
7.
Timer – when timer is stopped, resets the timer run value to the timer set
value
RECALL Button
1.
Stopwatch – recalls memory data for lap/split timing
2.
Speed – hold for 2 seconds to activate value setting mode
3.
Stroke – n/a
4.
Time/Calendar – hold for 2 seconds to activate time/date setting mode
5.
Alarm – hold for 2 seconds activate daily alarm setting mode
6.
Pacer – n/a
7.
Timer – hold for 2 seconds to activate value setting mode
MODE Button
Advances display through the stopwatch functions.
OPERATION
Entering Timing Modes
1.
Pressing the MODE button will advance the screen through the seven
functions of the stopwatch.
2.
Repeatedly pressing the mode button scrolls through the functions in the
following order: Stopwatch (Chron), Speed, Stroke, Time/Calendar, Alarm,
Pacer and Timer. With the exception of the Time/Calendar mode, an
identifying screen that displays for 2 seconds precedes each of modes.
Clearing the display
The RESET / LAP SPLIT button will clear the following displays:
1.
Stopwatch – resets the timer to zero
2.
Speed – resets the timer to zero
3.
Stroke – resets the timer value to 2400.0
4.
Pacer – starts and stops pacer function
5.
Timer – after timer is stopped, will reset the timer to set value
Clock Operation/Setting Time-of-Day & Date
1.
Press the MODE button to cycle through the displays until Time/Calendar
display is reached.
2.
Hold the RECALL button for 2 seconds, a beep will sound and the AM/PM
icon and hour digit will flash.
3.
The RESET/LAP SPLIT button will cycle through the Time/Calendar display
in the following order: hours, minutes, seconds, year, month and day.
4.
While in each of the above time measurements, each press of the
START/STOP button will advance one increment at a time, holding the
START/STOP button down enables rapid advancement.
5.
The “day of the week” feature will update automatically as the year, month
and day are changed.
6.
Save the set time and calendar reading by pressing RECALL. The display
will stop flashing.
Daily Alarm Operations
1.
Press the MODE button to cycle through the displays to the Alarm display.
2.
Hold down the RECALL button for 2 seconds, a beep will sound and the
AM/PM icon and hour digit of the alarm display will flash.
3.
Press the START/STOP button to advance the hourly setting of the alarm.
An “A” or “P” will be displayed indicating AM or PM alarm time.
4.
Press RESET to advance the minute.
5.
Press START/STOP to advance the digits.
6.
Press RECALL to set alarm.
7.
Press the RESET/LAP SPLIT button for 2 seconds to toggle the alarm icon
on and off. The (((•))) icon indicates alarm is on.
8.
When the alarm time is reached an audible alarm will sound for 30
seconds, or may be manually silenced by pressing the RESET/LAP SPLIT
button.
Pacer Operation
1.
Press the MODE button to cycle through the display modes to the Pacer
display. The last value set will be displayed on the screen.
2.
Pressing the RESET/LAP SPLIT button will advance through the pacer
values. The Pacer timer may be set at the following values: 5, 10, 20, 30,
40, 50, 60, 80, 100, 110, 120, 140, 160, 180, 200 and 240. These values
represent counts per minute (i.e., Pacer Value 20 = 20 beeps per minute)
3.
Press the START/STOP button to start the pacer timer. The flashing
PACER icon under the timer value indicates the timer is activated. An
audible alarm will sound representing the set pacer value.
4.
The pacer values can be changed while the timer is in operation. The pacer
alarm will change accordingly.
5.
Pressing the START/STOP button will turn off the pacer timer.
Timer - Countdown/Count up Mode
1.
Press to MODE button to cycle through the display modes to the Timer
display.
2.
Hold down the RESET/LAP SPLIT button for 2 seconds, a beep will sound
and the timer will toggle between countdown/countup mode (TIMER) and
repeat countdown mode (TIMER).
3.
To set countdown/countup mode, toggle to the TIMER icon.
4.
The top line of the 2-line display represents the time set value. The
maximum setting for this mode is 9 hours, 59 minutes and 59 seconds.
5.
To set the time value hold the RECALL button for 2 seconds. A beep will
sound and the hourly time increment will flash. Pressing the RESET/ LAP
SPLIT button will scroll through each time increment in the following order:
hours, minutes and seconds.
6.
Each press of the START/STOP button will advance one increment at a
time, holding down the START/STOP button enables rapid advancement.
7.
Press the RECALL button to lock in the countdown value.
8.
Press the START/STOP button, timing will begin and the timer icon will
show an arrow pointing down indicating countdown mode.
9.
If a pause in the timing operation is required press the START/STOP
button to “freeze” the display at the current reading (time-out). To resume
time at the point it was stopped, press the START/STOP button again
(time-in). An unlimited number of timeouts may be taken.
10. When the set countdown time value has been reached, a 30-second alarm
will sound. The alarm and timer can be manually stopped by pressing the
START/STOP button. Pressing the RECALL or RESET/LAP SPLIT will
silence the alarm and allow continued timing.
11. The TIMER icon will display indicating the count up mode. The timer will
show time passed since alarm time and will continue timing to 9 hours, 59
minutes and 59 seconds.
Timer - Repeat Countdown Mode
1.
With the display in timer mode, hold down the RESET/LAP SPLIT button
for 2 seconds. A beep will sound and the Repeat Counter display (00) will
appear in the upper left corner of the display. The TIMER icon at the
bottom of the screen indicates repeat countdown mode.
2.
To set the time value hold the RECALL button for 2 seconds. A beep will
sound and the hourly time increment will flash. Pressing the RESET/ LAP
SPLIT button will scroll through each time increment in the following order:
hours, minutes and seconds.
3.
Each press of the START/STOP button will advance one increment at a
time. Holding down the START/STOP button enables rapid advancement.
4.
Press the RECALL button to lock in the countdown value.
5.
Pressing the START/STOP button will begin the countdown. To stop the
countdown, press the START/STOP button and the STOP icon will appear
to the left of the countdown line.
6.
If a pause in the timing operation is required, press the START/STOP
button to “freeze” the display at the current reading (time-out). To resume
time at the point it was stopped, press the START/STOP button again
(time-in). An unlimited number of timeouts may be taken.
7.
An alarm will sound for 3 seconds when the set timer value has been
reached and the display will return to the set time value.
8.
The repeat mode allows continuous timing of the set timer value. The
repeat counter will show the number of times that the set timer value has
been reached. The counter can record up to 99 laps.
Single Action Timing
1.
Press the MODE button to advance the display to the stopwatch mode
indicated by the CHRON screen.
NOTE
: If there is a measured time event showing on the SPEED display, the
CHRON stopwatch mode will not be displayed. The SPEED display must be
reset to zero to use the stopwatch functions.
2.
This CHRON screen consists of a 3-line display indicating split timing on
the top line, lap timing on the middle line, and stopwatch timing on the
bottom line.
3.
Press RESET to set the counter to zero.
4.
The START/STOP button will begin stopwatch timing.
TRACEABLE
®
300-MEMORY STOPWATCH INSTRUCTIONS