DIN-Rail 8-Channel Relay Switch
Wiring Guide
Supported model
• C4-DIN-8RELSW-E DIN-Rail 8-Channel Relay Switch
Diagrams color code*:
Black
Line
Red
Load
Grey
Neutral
Green
Earth ground
Blue
Ethernet
*Important!
The wire colors shown in Figure 1 in the “Diagrams
color code” table are examples only. Actual wire colors differ by
country and/or voltage.
Wiring diagrams
Use these Control4 DIN-Rail 8-Channel Relay Switch wiring diagrams along
with the
DIN-Rail 8-Channel Relay Switch Installation Guide
(
ctrl4.co/8chrelay-ig
) to install DIN-Rail 8-Channel Relay Switches.
Figure 1. Wiring in Control4 panel
To E
therne
t s
wit
ch
Distribution
(breaker)
panel
Override switch
Load 1
Load 2
Line 1
Neutral Out 1
Neutral Out 2
Neutral In 1
Aux Override In
Aux Override Out
Ground
Load 3
Load 4
Line 2
Load 5
Load 6
Line 3
Load 7
Load 8
Line 4
Neutral Out 3
Neutral Out 4
Neutral In 2
Neutral Out 5
Neutral Out 6
Neutral In 3
Neutral Out 7
Neutral Out 8
Neutral In 4
Terminal block
Important
: Remove the four bypass
jumpers that connect each black
terminal to two red terminals by
unscrewing all three screws in each
bypass jumper until the entire bypass
jumper can be pulled out.
C4-DIN-8RELSW-E
8-Channel
Rel
ay Switch
AT
TE
NT
IO
N:
R
isq
ue
de
ch
oc
éle
ctr
iqu
e
Ne
p
as
ou
vrir
This device complies with part 15 of the FCC rules and ISED’
s
license-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
CAN ICES-3 (B)/NMB-3(B)
100-277V ,50/60 Hz
240V ,50 Hz
64A
Max T
otal
16A
Max per Circuit
16A
Max per Channel
1 HP
Max per Channel @ 120V
2 HP
Max per Channel @240V
Refer to documentation
for load ratings
Patent Pending
Load 3
Load 4
Load 5
Load 6
Load 7
Load 8
Load 1
Load 2
Neutral 1
Line 1
Neutral 2
Line 2
Neutral 3
Line 3
Neutral 4
Line 4
Aux in
Aux out
Load 3
Load 4
Load 5
Load 6
Load 7
Load 8
Note:
When less than four lines are
being used, jumper any
shared neutrals at the
Terminal Block