Rear Panel Connections
Ethernet
RJ-45 jack, 100Mbps for control, web page access, configuration, and firmware updates
RS-232 Control
DB-9 male RS-232 data link for control, configuration, and firmware updates
USB Control
USB mini-B jack virtual com port for control, configurations, and firmware updates
I/O
Logic control port 6-pin captive screw terminal
1
–
PWR+
Power, 12 VDC, 250 mA max (using the included 500 mA power supply)
2
–
OUT2
Output 2
3
–
OUT1
Output 1
4
–
IN2
Input 2
5
–
IN1
Input 1
6
–
GND-
Ground
Power In
2.1 mm coaxial jack (inside center conductor positive), 11 to 18 VDC, 12 VDC typical, 250 mA maximum
RF In
‘F’ female 75 ohm impedance for future use
RF Out
‘F’ female, 75 ohm impedance, RF to CATV distribution
system
Data Transmit: Mid-band VHF, 74.7 MHz, +14 to +45 dBmV, adjustable from front panel