Contemporary Research ICC1-IRX Скачать руководство пользователя страница 7

Contemporary Research 

ICC1-IRX 

 

Installation

 

IR Control Codes 

 

Code 

+CSM 

MFG 

Display 

Power 

Notes 

Ver 

65 

Zenith 

TV 

CC-HSD  

Use CC-HSD  

1.2 

66 

Panasonic 

TV 

CC-HSD  

Use CC-HSD  

1.0 

67 

Toshiba 

TV 

CC-HSD  

Use CC-HSD  

1.5 

68 

Hitachi 

TV 

CC-HSD  

Use CC-HSD  

1.5 

69 

Sony/Westinghouse LCD 

TV 

CC-HSD  

Use CC-HSD  

1.5 

70 

Grundig 

TV 

CC-HSD  

Use CC-HSD  

1.6 

71 

Magnavox/Philips 

TV 

CC-HSD  

Use CC-HSD  

1.7 

72 

RCA 

TV 

CC-HSD  

Use CC-HSD  

1.7 

73 

Sony 2 

TV 

CC-HSD  

Use CC-HSD  

1.8 

10 

74 

Panasonic 2 

TV 

CC-HSD  

Use CC-HSD  

1.9 

11 

75 

Mitsubishi 

TV 

CC-HSD  

Use CC-HSD  

1.9 

12 

76 

Finlux 

TV 

CC-HSD  

Not in V 2.2-2.3 

3.0 

14 

77 

Panasonic 3  

TV 

CC-HSD  

Use CC-HSD  

2.0 

15 

78 

Sharp  

TV 

CC-HSD  

Use CC-HSD  

2.0 

19 

83 

JVC 

TV 

CC-HSD  

Use CC-HSD  

2.1 

20 

84 

ViewSonic Tuner 

Tuner 

N/A 

 

2.2 

21 

 

LG/Zenith_2 

PDP/LCD 

Discrete 

 

5.6 

22 

 

Philips_ 

PDP/LCD/TV 

CSM1 

 

3.1 

23 

 

JVC_2 

PDP/LCD/TV 

CSM1 

 

3.2 

24 

 

 

Sampo .NetTV, Gateway 
ViewSonic  

PDP/LCD/TV 

Discrete 

 

3.2 

25 

 

Samsung 

PDP/HD 

Discrete 

14-second delay 

4.4 

26 

90 

Gateway 

LCD 

CSM1 

 

3.3 

27 

91 

Viewsonic LCD 

LCD 

CSM1 

 

3.4 

28 

 

JVC_3 

TV 

Discrete 

1-Digit tuning, 1-9 

3.5 

29 

93 

LG/Zenith/Dell_3 

PDP/LCD 

CSM1 

 

3.5 

30 

 

Sharp_2 

PDP/LCD 

Discrete 

 

3.7 

31 

95 

Daewoo 

TV 

CSM1 

 

3.7 

32 

96 

Viewsonic LCD 2 

LCD 

CSM1 

 

3.8 

33 

 

H&B 

PDP/LCD 

Discrete 

B Series 

4.0 

34 

 

H&B 

PDP/LCD 

Discrete 

V Series 

4.0 

35 

 

Sony 

PDP/LCD 

Discrete 

 

4.0 

36 

100 

Dell W4201C (RC6) 

LCD 

CSM1 

 

4.1 

37 

101 

NEC LCD 

LCD 

Discrete 

 

6.2 

38 

102 

Olevia 

LCD 

CSM1 

26-sec power on delay  

4.2 

39 

103 

Akai 

LCD 

CSM1 

 8-second delay 

4.7 

40 

104 

Sanyo 

TV 

CSM1 

Use CC-HSD  

4.3 

41 

105 

ILO/Insignia/Dynex/Zenith 

TV 

CSM1 

Use CC-HSD 

4.3 

42 

 

Viewsonic LCD 

LCD 

Discrete 

Input selects 

5.0 

43 

 

Sony  

LCD 

Discrete 

FWD-50PX2 

5.2 

44 

 

Vizio 

LCD 

Discrete 

Input selects 

5.3 

45 

 

Panasonic 

LCD 

Discrete 

Input selects 

5.4 

46 

 

Sharp_3 

LCD 

Discrete 

Fixes dash tuning 

5.7 

47 

111 

Sylvania  

LCD 

CSM1 

SRT902A 

6.0 

48 

 

Toshiba 3 

LCD 

Discrete 

 

6.5 

49 

 

Philips RC6 

LCD 

Discrete 

 

6.6 

51 

115 

Scientific Atlanta 

Cable Box 

CSM1 

8300HD 

6.7 

52 

 

Insignia, Dynex 

LCD 

Discrete 

 

6.8 

53 

 

Samsung 2 

LCD 

Discrete 

On Off  

7.1 

55 

119 

Motorola STB 

Cable Box 

CSM1 

 

 

56 

120 

DirecTV 

Satellite Receiver 

CSM1 

 

 

57 

121 

Tote Vision 

TV 

CSM1 

 

 

 

PC Sensor Setup:

 LCDs marked 

CSM1

 or

 CC-HSD 

do not have discrete IR power commands. The first Code number is set to look for the 

sensor to know if the TV is on or off. If you want to use unsensed toggling power instead, use the 

CSM

 code. Instead, the ICC1-IRX will 

wait for an “OFF” signal from a

 power sensor before it sends an ON IR command. This adds 64 to the base code number.  

If you use the DIP switches, turn DIP S1, Switch 7 ON when you set the IR code with the DIP switches. If you are using IC-Send or Display 
Express Special Command feature, send the command T1, with the IR code value + 64. For example, to set Olevia controllers to toggling 
power, send the command T1, 102 (38+64). 

 

Содержание ICC1-IRX

Страница 1: ...Contemporary Research 1 ICC1 IRX Product Manual ICC1 IRX IR TV Controller 1 way RF Coax Control November 28 2017...

Страница 2: ...Installation 5 Installation 6 Using Display Express or IC Send Software 10 Display Express 11 RS 232 Control Protocol 12 Writing Your Own Control Code 13 RS 232 Commands 14 RS 232 Commands 15 iC Net Z...

Страница 3: ...ications include sports and entertainment venues commercial and civic facilities airports factories schools and houses of worship Controls most brands of IR controlled TVs Delivers discrete power comm...

Страница 4: ...IP 3 5mm jack for optional CC HSD scan sensor Also acts as logic level input switch to GND to signal power on CSM1 3 5mm jack for power and data from CSM1 power current sensor Power Sensor LED Red LED...

Страница 5: ...nce per second 4 Connect the RF loop cable from the RF Out jack to the TV s RF connector you lose less than 1 5 dBmV going through the ICC1 IRX S internal RF tap TV Power Sensing 1 To sense power on f...

Страница 6: ...3 4 and 6 which adds 2 4 8 32 46 7 When you turn switch 6 off your IRX will now output the latest Sharp codes 8 You can add options to your basic code as well For example if you re not using a CSM1 fo...

Страница 7: ...iscrete 4 0 36 100 Dell W4201C RC6 LCD CSM1 4 1 37 101 NEC LCD LCD Discrete 6 2 38 102 Olevia LCD CSM1 26 sec power on delay 4 2 39 103 Akai LCD CSM1 8 second delay 4 7 40 104 Sanyo TV CSM1 Use CC HSD...

Страница 8: ...Make sure S2 Switch 6 is OFF unit in Device mode 2 Set the Device number by turning on the switches that add up to the desired device number For example for Device 259 turn on S1 switches 1 and 2 3 S2...

Страница 9: ...The first identifies the location name of the display The second shows the specific address The last set shows the switches in S1 S2 that are set to ON It s a good idea to define all this first in a s...

Страница 10: ...nged For example to change the IR code set for a controller enter T1 in the first field the code listed on page 7 then the device of the controller For example to set the controller to Sharp use T1 an...

Страница 11: ...Edit page to send the same command Select the TV s you want to change check Use Commands and Command String then enter T1 code example T1 46 for Sharp TVs Click Send to send the command If you haven t...

Страница 12: ...Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well The address 4095 triggers all devices...

Страница 13: ...15 hex 1 F Unit 1 255 hex 1 FF Bytes Number of bytes that follow Command 1 byte Parameters 1 to 4 bytes String Format Every software application has a different denotation for handling hex ASCII and...

Страница 14: ...e formats below 128 Add Enter after channel number 105 Enter 64 Add 100 to channel number 105 100 05 use 3 digit tuning 3 3 digits Ex 007 032 105 ICC1 IRX inserts leading zeros if needed 2 2 digits Ex...

Страница 15: ...sensor When the control is locked the display is locked to the power state of the ICC1 IRX For example if the ICC1 IRX power state is off the display can t be turned on from the IR remote or TV front...

Страница 16: ...Refer to the code numbers on page 21 in the 232 ATSC 1 manual For example sending LQ 25 will pulse a Volume Up command and LQ 25 is Volume down If you re using a custom control system repeat the comma...

Страница 17: ...ller s Zone You could stop at that point or use the upper switches S1 to define the controller s address within the Zone For example setting S2 1 On and S1 2 On defines that the controller is part of...

Страница 18: ...151 257 1 1 W152 258 2 1 W153 259 1 2 1 W154 260 3 1 2 W 2nd Floor 512 W251 513 1 2 W252 514 2 2 W253 515 1 2 2 W254 516 3 2 3 E 1st Floor 768 E151 769 1 1 2 E152 770 2 1 2 E153 771 1 2 1 2 E154 772 3...

Страница 19: ...ttempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 9 Damage Requiring Service...

Отзывы: