232 Control Protocol

 

 

Overview 

 
RS-232 control for up to 4000 TV Controllers is provided through an iC-series Head-End Network Controller. The ICC-HE 
Head-End manages iC-Net communication over RF Coax to ICC1 (1-way) and ICC2 (2-Way) TV Controllers as well as ICW TV 
Controllers over twisted-pair Cat3/5 wiring. The ICW-HE Head-End operates on the twisted-pair network only. 
 
Each TV Controller is assigned a unique device number from 1 to 4000 to which control commands are addressed. The 

devices are organized into 16 zones of 255 devices. All the devices in each zone will respond to a single “virtual device 
number” —

 one device number that represents all devices in each zone. There is also a global device number, 4095, that 

will command all devices in the system. This feature dramatically speeds up system operation and programming, because 
one command can affect an entire group of devices

or all. To take advantages of this feature, review the section 

iC-Net 

Zones 

in this manual.  

 
In Display Express System, we reserve the first group of devices, 1-255, for components operating on a connected control 
system. Zones 1-

16 are used for CR TV Controllers, Video Display Controllers and Tuners. As it’s unlikely any system w

ill 

use all 4000 devices, this may be a good device standard for your system as well. The address 4095 triggers all devices.  
 
The Remote RS-232 port on the Head-End Network Controller can communicate from 1200 to 38.4K baud. The factory 
default setting is 19.2K baud, 8 data bits, No parity, and 1 stop bit.   

 

Command String Structure 

 
Characters in command strings are expressed in a combination of hex and ASCII characters. For clarity, the following 
protocol examples use the following conventions: 
 

 

Single-

byte hex numbers are preceded by the ‘$’ symbol

 

 

ASCII characters or strings are enclosed in single quotes 

 

Numbers not marked as hex or ASCII are a single decimal byte 

 

Parameters shown in < > brackets are single byte  

 

A series of multiple commands or parameters are set apart by [ ] brackets 

 

Commas separate the bytes, but are not part of the protocol 

 

Double quotes enclose the command string, but are not part of the protocol 

 

Command format: 

 

“$A5,<dh>,<dl>,<ncb>,<cmd1>,<parameter> [<cmdN>]"

 

 

$A5 

Starts the command

 

<dh> 

The zone or high order byte of the device [hex] 

<dl> 

The unit or low order byte of the device (0 for global zone)

 

 

<ncb>

 

The number of command bytes to follow  

<cmd1>

 

The first command byte 

<parameter> 

Command

 

parameters (not used by all commands) 

[<cmdN>] 

Multiple commands can be concatenated, with byte count added to <ncb> 

 

Содержание ICC1-IRX

Страница 1: ...Contemporary Research 1 ICC1 IRX Product Manual ICC1 IRX IR TV Controller 1 way RF Coax Control November 28 2017...

Страница 2: ...Installation 5 Installation 6 Using Display Express or IC Send Software 10 Display Express 11 RS 232 Control Protocol 12 Writing Your Own Control Code 13 RS 232 Commands 14 RS 232 Commands 15 iC Net Z...

Страница 3: ...ications include sports and entertainment venues commercial and civic facilities airports factories schools and houses of worship Controls most brands of IR controlled TVs Delivers discrete power comm...

Страница 4: ...IP 3 5mm jack for optional CC HSD scan sensor Also acts as logic level input switch to GND to signal power on CSM1 3 5mm jack for power and data from CSM1 power current sensor Power Sensor LED Red LED...

Страница 5: ...nce per second 4 Connect the RF loop cable from the RF Out jack to the TV s RF connector you lose less than 1 5 dBmV going through the ICC1 IRX S internal RF tap TV Power Sensing 1 To sense power on f...

Страница 6: ...3 4 and 6 which adds 2 4 8 32 46 7 When you turn switch 6 off your IRX will now output the latest Sharp codes 8 You can add options to your basic code as well For example if you re not using a CSM1 fo...

Страница 7: ...iscrete 4 0 36 100 Dell W4201C RC6 LCD CSM1 4 1 37 101 NEC LCD LCD Discrete 6 2 38 102 Olevia LCD CSM1 26 sec power on delay 4 2 39 103 Akai LCD CSM1 8 second delay 4 7 40 104 Sanyo TV CSM1 Use CC HSD...

Страница 8: ...Make sure S2 Switch 6 is OFF unit in Device mode 2 Set the Device number by turning on the switches that add up to the desired device number For example for Device 259 turn on S1 switches 1 and 2 3 S2...

Страница 9: ...The first identifies the location name of the display The second shows the specific address The last set shows the switches in S1 S2 that are set to ON It s a good idea to define all this first in a s...

Страница 10: ...nged For example to change the IR code set for a controller enter T1 in the first field the code listed on page 7 then the device of the controller For example to set the controller to Sharp use T1 an...

Страница 11: ...Edit page to send the same command Select the TV s you want to change check Use Commands and Command String then enter T1 code example T1 46 for Sharp TVs Click Send to send the command If you haven t...

Страница 12: ...Controllers Video Display Controllers and Tuners As it s unlikely any system will use all 4000 devices this may be a good device standard for your system as well The address 4095 triggers all devices...

Страница 13: ...15 hex 1 F Unit 1 255 hex 1 FF Bytes Number of bytes that follow Command 1 byte Parameters 1 to 4 bytes String Format Every software application has a different denotation for handling hex ASCII and...

Страница 14: ...e formats below 128 Add Enter after channel number 105 Enter 64 Add 100 to channel number 105 100 05 use 3 digit tuning 3 3 digits Ex 007 032 105 ICC1 IRX inserts leading zeros if needed 2 2 digits Ex...

Страница 15: ...sensor When the control is locked the display is locked to the power state of the ICC1 IRX For example if the ICC1 IRX power state is off the display can t be turned on from the IR remote or TV front...

Страница 16: ...Refer to the code numbers on page 21 in the 232 ATSC 1 manual For example sending LQ 25 will pulse a Volume Up command and LQ 25 is Volume down If you re using a custom control system repeat the comma...

Страница 17: ...ller s Zone You could stop at that point or use the upper switches S1 to define the controller s address within the Zone For example setting S2 1 On and S1 2 On defines that the controller is part of...

Страница 18: ...151 257 1 1 W152 258 2 1 W153 259 1 2 1 W154 260 3 1 2 W 2nd Floor 512 W251 513 1 2 W252 514 2 2 W253 515 1 2 2 W254 516 3 2 3 E 1st Floor 768 E151 769 1 1 2 E152 770 2 1 2 E153 771 1 2 1 2 E154 772 3...

Страница 19: ...ttempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 9 Damage Requiring Service...

Отзывы: