Product Nomenclature and Function
—
SH-9008AT-POE Reference Manual
- 23 -
2.
Connection Restrictions
Connection Restrictions with 100BASE-TX Repeater HUBs
At Class I, cascade connection with 100BASE-TX repeater HUBs is impossible. Up to two stages of
cascade connection between 100BASE-TX Class II repeaters is possible. In addition, the total
maximum cable length of cables (1)(2)(3) is 205m or less. For details, see the operation manual of
your 100BASE-TX repeater HUB.
Connection Restrictions with 10BASE-T Repeater HUBs
As many as four stages of 10BASE-T repeater HUBs can be connected using cascade connection. In
addition, the maximum length of UTP and STP cables between cascaded HUBs is 100m. For details,
see the operation manual of your 10BASE-T repeater HUB.