Contec GMB-L3WHL200 Скачать руководство пользователя страница 71

 

71

  -

 

Appendix

 

This section lists the specifications and components 
suggestion, block diagram, driver installation, and 
mechanical drawing. 

 

 

 

Содержание GMB-L3WHL200

Страница 1: ...Manual CONTENTS Industrial Mainboard GMB L3WHL200 Introduction 5 Safety Precautions 11 Product Nomenclature and Function 17 BIOS Setup 48 Appendix 70 List of Optional Products 75 Customer Support and...

Страница 2: ...tion JP4 21 5 ROM Clear Select Jumper JBAT2 22 3 Connector List 23 1 DC IN Power Connector CN5 25 2 LVDS_Backlight PW Connector CN2 25 3 SATA Power Connector SATAPW1 26 4 CPU FAN Connector 4P CPUFAN1...

Страница 3: ...53 4 Advanced 54 1 CPU Configuration 55 2 PCH FW Configuration 56 3 Trusted Computing 57 4 ACPI Settings 58 5 Super IO Configuration 59 6 H W Monitor 61 7 USB Configuration 62 5 Chipset 64 1 System A...

Страница 4: ...4 Table of Contents Customer Support and Inquiry 83 1 Services 84...

Страница 5: ...5 Introduction This section provides necessary information of the product such as the outline bundled items and manuals before actual use...

Страница 6: ...h this document Must Read the Following Manuals Name Purpose Contents How to get Reference Manual Read this when operating the product This describes the hardware aspects such as functions and setting...

Страница 7: ...in DDR4 2400 SO DIMM socket for up to 16GB of memory To meet customer various needs it also equipped with one Full sized Mini PCIe slot M 2 M key with mSATA support and M 2 E key with SIM socket In ad...

Страница 8: ...Manual 8 3 Features Intel 8th Gen Core i3 8145UE Processor whiskey Lake U Support 1 x DDR4 2400 SO DIMM up to 16 GB Equip 1 x Full sized Mini PCIe 1 x M 2 2280 Key M and 1 x M 2 2230 Key E Support Tri...

Страница 9: ...Introduction GMB L3WHL200 Reference Manual 9 4 Supported OS Windows 10 IoT Enterprise LTSC 2019 64 bit...

Страница 10: ...Conn 1 Screw for fixing M 2 M key card M3x6 with Standoff 1 Screw for fixing Mini PCIe card M2x5 1 1 The configuration and parts of this product are shown below 2 The user manual for this product is a...

Страница 11: ...11 Safety Precautions Understand the following definitions and precautions to use the product safely Never fail to read them before using the product...

Страница 12: ...t avoided it will result in death or serious injury WARNING WARNING indicates a hazard with a medium risk level If this hazardous situation is not avoided it could result in death or serious injury CA...

Страница 13: ...ls on replacing the battery refer to the appendix This product is connected to a socket outlet with earthing connection by means of a power cord This product is not suitable for use in locations where...

Страница 14: ...vent corruption of files always shutdown the OS before turning off this product CONTEC reserves the rOKight to refuse to service a product modified by the user In the event of failure or abnormality f...

Страница 15: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 16: ...tended operations 2 Security measures e g Do not keep using the default password Refer to the product manual for the password setting Set a strong password Combined with upper and lowercase letters an...

Страница 17: ...17 Product Nomenclature and Function This section describes product component names and their functions pin assignment of each connector...

Страница 18: ...Product Nomenclature and Function GMB L3WHL200 Reference Manual 18 1 Product Overview connectors of the product are shown in the picture below Top View...

Страница 19: ...e GMB L3WHL200 features In the following sections short means covering a jumper cap over jumper pins Open or N C not connected means removing a jumper cap from jumper pins Users can refer to below Top...

Страница 20: ...curity Override JP1 PIN No Jumper Description 1 2 Open Default 0 Enable security measures defined in the Flash Descriptor 2 3 Short 1 Disable Flash Descriptor Security override 2 AT ATX Mode Select JP...

Страница 21: ...LED BL Power Selection JP3 PIN No Jumper Description 1 2 Short Default Normal Operation 2 3 Short ROM Clear Contents 4 LVDS_Panel Power Selection JP4 PIN No Jumper Description 1 2 Short Default Norma...

Страница 22: ...duct Nomenclature and Function GMB L3WHL200 Reference Manual 22 5 ROM Clear Select Jumper JBAT2 PIN No Jumper Description 1 2 Short Default Normal Operation 2 3 Short ROM Clear Contents JBAT2 JBAT2 2...

Страница 23: ...nnector Ref label Ref label Ref label Ref label 1 DP1 9 SATA2 14 F_PANEL1 22 SO DIMM1 2 HDMI1 10 SATA1 15 CPUFAN1 23 CN2 3 LAN2 11 COM1 16 SPI1 24 CN4 4 LAN1 COM2 17 MINI_CARD1 25 BATTERY1 5 USB3 COM3...

Страница 24: ...S TB 11 2 COM2 4 RS 232 9P JST BM09B SRSS TB 12 SATAPW1 SATA power connector 13 GPIO1 16 bit GPIO Pin header 14 F_PANEL1 Front Panel Pin header Power SATA LED Reset PWR button 15 CPUFAN1 CPU FAN conne...

Страница 25: ...tion GMB L3WHL200 Reference Manual 25 1 DC IN Power Connector CN5 PIN No Signal Description 1 DC IN 2 GND 2 LVDS_Backlight PW Connector CN2 PIN No Signal Description 1 LVDS_LCD_VDD 2 GND 3 BL_EN 4 BKL...

Страница 26: ...WHL200 Reference Manual 26 3 SATA Power Connector SATAPW1 PIN No Signal Description 1 5Vdc 2 GND 3 GND 4 5Vdc 4 CPU FAN Connector 4P CPUFAN1 PIN No Signal Description 1 GND 2 12Vdc 3 FAN_SPEED_OUT 4 F...

Страница 27: ...o Signal Description PIN No Signal Description 8 GND 7 RST_SW 6 PWRBTN 5 GND 4 PWR LED 3 HDDLED 2 PWR LED 1 HDDLED 6 Audio Pin HDR 8P AUDIO1 PIN No Signal Description PIN No Signal Description 8 A_FRO...

Страница 28: ...ature and Function GMB L3WHL200 Reference Manual 28 7 USB2 0 Pin HDR 10P USB2 PIN No Signal Description PIN No Signal Description 1 GNG 3 GND 4 GND 5 USB D5 6 USB D6 7 USB D5 8 USB D6 9 5V_USB 10 5V_U...

Страница 29: ...ature and Function GMB L3WHL200 Reference Manual 29 8 Debug Port LPC Interface Conn 9P CN3 PIN No Signal Description 1 3 3V 2 DBG_PLTRST 3 LPC_FRAME 4 LPC_AD0 5 LPC_AD1 6 LPC_AD2 7 LPC_AD3 8 GND 9 CLK...

Страница 30: ...L 1 14 LVDS_A_TXL 0 15 LVDS_A_TXL 1 16 LVDS_A_TXL 0 17 GND 18 GND 19 LVDS_A_TXL 3 20 LVDS_A_TXL 2 21 LVDS_A_TXL 3 22 LVDS_A_TXL 2 23 GND 24 GND 25 LVDS_B_TXL 1 26 LVDS_B_TXL 0 27 LVDS_B_TXL 1 28 LVDS_...

Страница 31: ...O1 PIN No Signal Description PIN No Signal Description 20 GND 19 5VSB 18 GND 17 5VSB 16 DIO_16 15 DIO_15 14 DIO_14 13 DIO_13 12 DIO_12 11 DIO_11 10 DIO_10 9 DIO_9 8 DIO_8 7 DIO_7 6 DIO_6 5 DIO_5 4 DIO...

Страница 32: ...ture and Function GMB L3WHL200 Reference Manual 32 11 SPI Connector 9P SPI1 PIN No Signal Description 1 3 3V_SPI 2 SPIROM_SCK 3 SPI_TPM_RST 4 SPIROM_SI 5 SPI_PIRQ 6 SPIROM_SO 7 NC 8 SPIROM_CS0 1 9 SPI...

Страница 33: ...0 Reference Manual 33 12 Serial Port RS 232 422 485 9P COM1 PIN No Signal Description RS 232 RS 422 RS 485 1 DCD 1 TX TX 2 RX 1 TX TX 3 TX 1 RX RX 4 DTR 1 RX RX 5 GND GND GND 6 DSR 1 RTS NC 7 RTS 1 RT...

Страница 34: ...nclature and Function GMB L3WHL200 Reference Manual 34 13 Serial Port RS 232 9P COM2 COM4 PIN No Signal Description 1 DCD n 2 RX n 3 TX n 4 DTR n 5 GND 6 DSR n 7 RTS n 8 CTS n 9 RI n 1 9 1 9 1 9 COM3...

Страница 35: ...uct Nomenclature and Function GMB L3WHL200 Reference Manual 35 14 RTC Battery Connector BATTERY1 PIN No Signal Description 1 3V DC 2 GND CAUTION The connector of RTC Battery has and polarities BATTERY...

Страница 36: ...PIN No Signal Description C1 UIM_PWR C2 UIM_RESET C3 UIM_CLK C4 GND C5 UIM_VPP C7 UIM_DATA CAUTION 1 Slide the socket lid Unlock as Figure A 2 Open the socket lid place the card into the socket 3 Clo...

Страница 37: ...ATA1 SATA2 Two SATA 3 1 Gen2 10 Gb s Port 17 M 2 E Key Socket M2_1 M 2 E Key Socket PCIe USB Signal The board has one mechanical connector key E accepting type 2230 of M 2 modules H 4 2mm SATA 1 SATA...

Страница 38: ...les H 8 5mm double sided 19 Mini Card Socket MINI_CARD1 Mini Card Socket PCIe USB Signal The board has one mechanical connector Mini card accepting full sized modules M 2 M Key Screw Size Thread Size...

Страница 39: ...n GMB L3WHL200 Reference Manual 39 20 USB Connector USB1 USB3 USB1 USB3 USB3 2 Gen2 Type A PIN No Signal Description PIN No Signal Description 1 VCC 5 USB RX 2 USB D 6 USB RX 3 USB D 7 GND 4 GND 8 USB...

Страница 40: ...nd Function GMB L3WHL200 Reference Manual 40 21 Giga LAN RJ 45 Port LAN1 LAN2 RJ45 Connector RJ45 LEDs for display of network status PIN No Signal Description 1 TX1 2 TX1 3 TX2 4 TX3 5 TX3 6 TX2 7 TX4...

Страница 41: ...t HDMI1 PIN No Signal Description PIN No Signal Description 1 HDMI1 DATA2 2 GND 3 HDMI1 DATA2 4 HDMI1 DATA1 5 GND 6 HDMI1 DATA1 7 HDMI1 DATA0 8 GND 9 HDMI1 DATA0 10 HDMI1 CLK 11 GND 12 HDMI1 CLK 13 NC...

Страница 42: ...play Port DP1 PIN No Signal Description PIN No Signal Description 1 ML_Lane 0 2 GND 3 ML_Lane 0 4 ML_Lane 1 5 GND 6 ML_Lane 1 7 ML_Lane 2 8 GND 9 ML_Lane 2 10 ML_Lane 3 11 GND 12 ML_Lane 3 13 GND 14 G...

Страница 43: ...With this function running programs can be restarted in the usual way even if an abnormal state occurs The software can be configured using 255 levels 1 to 255 seconds of timeout intervals for the wa...

Страница 44: ...anguage WDT Initial Enter the extended function mode MOV DX 2EH MOV AL 87H OUT DX AL OUT DX AL Select logical device WDT number 8 MOV DX 2EH MOV AL 07H OUT DX AL MOV DX 2FH MOV AL 08H OUT DX AL Activa...

Страница 45: ...T counter set and a start Enter the extended function mode MOV DX 2EH MOV AL 87H OUT DX AL OUT DX AL Select logical device WDT number 8 MOV DX 2EH MOV AL 07H OUT DX AL MOV DX 2FH MOV AL 08H OUT DX AL...

Страница 46: ...X 2EH MOV AL AAH OUT DX AL WDT STOP Enter the extended function mode MOV DX 2EH MOV AL 87H OUT DX AL OUT DX AL Select logical device WDT number 8 MOV DX 2EH MOV AL 07H OUT DX AL MOV DX 2FH MOV AL 08H...

Страница 47: ...Product Nomenclature and Function GMB L3WHL200 Reference Manual 47 OUT DX AL Exit the extended function mode MOV DX 2EH MOV AL AAH OUT DX AL CAUTION The timer s intervals have a tolerance of 2 seconds...

Страница 48: ...48 BIOS Setup This section describes AMI s Setup program built into the FLASH ROM BIOS...

Страница 49: ...e disks and then launch and turn control over to the operating system While the BIOS is in control the Setup program can be activated in one of two ways By pressing Del or ESC immediately after switch...

Страница 50: ...key Optimized defaults F4 key Save Exit Setup 3 Getting Help Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item To...

Страница 51: ...ill appear on the screen The Main Menu allows you to select from several setup functions and exit choices Use the arrow keys to select among the items and press Enter to accept and enter the sub menu...

Страница 52: ...lock Advanced configure your CPU and other system devices for basic operation through the following sub menus Chipset Specify the detailed functions that can be set on the system used Security Set the...

Страница 53: ...plays the BIOS creation date and time Access Level Administrator Displays the access rights level Main Menu Selections Item Option Description System Language Choose system default language System Dat...

Страница 54: ...BIOS Setup GMB L3WHL200 Reference Manual 54 4 Advanced This section allows you to configure your CPU and other system devices for basic operation through the following sub menus...

Страница 55: ...cessor package Hyper Threading Disabled Enabled Enabled or Disabled hyper threading technology Boot Performance Mode Max Battery Max Non Turbo Performance Turbo Performance Select the performance stat...

Страница 56: ...bles enables manageability features support in FW To disable support platform must be in a provisioned state first AMT BIOS Features Disabled Enabled When disabled AMT BIOS features are no longer supp...

Страница 57: ...ns Description Security Device Support Disable Enable Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Страница 58: ...nabled Enables or Disables System ability to Hibernate OS S4 Sleep State This option may not be effective with some operating systems ACPI Sleep State Suspend Disabled S3 Suspend to RAM Select the hig...

Страница 59: ...t 2 Serial Port 3 Configuration Refer to Serial Port 3 Serial Port 4 Configuration Refer to Serial Port 4 Teach Panel Configuration Refer to Teach Panel Configuration Digital I O Configuration Refer t...

Страница 60: ...cription Serial Port Disabled Enabled Enable or Disable Serial Port COM Serial Port 4 Configuration Item Options Description Serial Port Disabled Enabled Enable or Disable Serial Port COM Teach Panel...

Страница 61: ...BIOS Setup GMB L3WHL200 Reference Manual 61 6 H W Monitor View hardware monitor information such as the CPU temperature...

Страница 62: ...able option will keep USB devices available only for EFI applications XHCI Hand off Enabled Disabled This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be cla...

Страница 63: ...ther Short or Extended Self Test Short option will take couple of minutes and extended option will take several minutes to complete Self Test Action Controller Only Test Controller and NameSpace Test...

Страница 64: ...PEG PCI graphic device should be primary display or select SG for switchable Gfx Internal Graphics Auto Disabled Enabled Keep IGFX enabled based on the setup options GTT Size 2MB 4MB 8MB Select the G...

Страница 65: ...el 4 Level 5 Level 6 Level 7 Level 8 Back light control setting LCD Panel Type 800 x 600 Single Channel 18bit 1024 x 768 Single Channel 18bit 1024 x 768 Single Channel 24bit 1280 x 768 Single Channel...

Страница 66: ...nabled Disabled Enable Disable integrated LAN to wake the system Wake on RI COM1 Enabled Disabled Enable Disable RI to wake the system Wake on RI COM2 4 Enabled Disabled Enable Disable RI to wake the...

Страница 67: ...Enabled Disabled Enable Disable SATA Device SATA Mode Selection AHCI Determines how SATA controllers operate HD Audio Configuration Item Options Description HD Audio Enabled Disabled Control Detectio...

Страница 68: ...ature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode The mode change requires platform reset Secure Boot Mode Standard Custom Secure Boot mode options S...

Страница 69: ...Enabled Disabled Enables or disables quite boot option Boot Option 1 UEFI Built in EFI Shell Windows Boot Manager INTEL Windows Boot Manager PO ATP Disabled Set the system boot order Boot Option 2 UE...

Страница 70: ...Any changes made to BIOS settings during this session of the BIOS setup program are discarded The setup program then exits and reboots the controller Restore Defaults This option restores all BIOS se...

Страница 71: ...71 Appendix This section lists the specifications and components suggestion block diagram driver installation and mechanical drawing...

Страница 72: ...2242 2280 for storage PCIe SATA Signal 1 x M 2 E Key 2230 for wireless LAN PCIe USB Signal Input Output 4 x Serial Port with pin header on board 1 x RS 232 422 485 3 x RS 232 6 x USB Port 4 x USB3 1...

Страница 73: ...Appendix GMB L3WHL200 Reference Manual 73 2 Block Diagram...

Страница 74: ...Appendix GMB L3WHL200 Reference Manual 74 3 Dimension...

Страница 75: ...otherboard 2 Memory Installation The DDR4 memory sockets are divided into A and B two channels each has two sockets showed as below 1 Locate the SO DIMM slot Align the notch on the DIMM with the key o...

Страница 76: ...Appendix GMB L3WHL200 Reference Manual 76 3 Mini PCIe Card Installation 1 Use M2x5 screw to fix mini PCIe card 2 Check if the mini PCIe card is loose...

Страница 77: ...ndix GMB L3WHL200 Reference Manual 77 4 M 2 M Key Card Installation For 2280 Card 1 Use 5mm socket screwdriver to fix M3x6 5 standoff first 2 Use M3x6 screw to fix M 2 card 3 Check if the M 2 card is...

Страница 78: ...ndix GMB L3WHL200 Reference Manual 78 5 M 2 M Key Card Installation For 2242 Card 1 Use 5mm socket screwdriver to fix M3x6 5 standoff first 2 Use M3x6 screw to fix M 2 card 3 Check if the M 2 card is...

Страница 79: ...Appendix GMB L3WHL200 Reference Manual 79 6 M 2 E Key Card Installation 1 Use M3x6 screw to fix M 2 card 2 Check if the M 2 card is loose...

Страница 80: ...Appendix GMB L3WHL200 Reference Manual 80 7 HDMI Installation 1 Use M3x8 screw to fix HDMI and I O panel...

Страница 81: ...81 List of Optional Products This section lists optional items that can be used along with the product...

Страница 82: ...as required Accessory Parts Name Product Code Description Heatspread LYYV851 LYYV861 SATA Power Cable LYYY341 SATA Cable LYYY271 Work with storage kit Audio Cable LYYY261 Mainboard DC IN Cable LYYY251...

Страница 83: ...83 Customer Support and Inquiry CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably...

Страница 84: ...seful information including product manuals that can be downloaded through the CONTEC website Download https www contec com download You can download updated driver software firmware and differential...

Страница 85: ...ant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify your retailer Regardless of the f...

Страница 86: ...u Osaka 555 0025 Japan https www contec com No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD GMB L3WHL200 Reference Manual N...

Отзывы: