4. Function
42
DIO-32DM2-PE
Generating function
Generating control
DIO-32DM2-PE can output (generate) pattern data at fixed intervals using a generating clock. The
table below lists the generating clock, generating start trigger, and generating stop trigger factors.
Table 4.2. generating clock, start trigger, stop trigger
Item
Factor
Contents
Generating
clock
Internal clock
Internal clock (50ns to 107s)
25nsec unit
External clock
Fall of external clock input (EXTCLK1)
(Maximum frequency response: 10 MHz)
Handshake
Rise of handshake signal (EXTACK1)
SC connector
Clock input from synchronization control connector
(Maximum frequency response: 5 MHz)
Generating
start trigger
Software
Software command
Rise of external signal
Rise of external start signal (EXTSTART1)
Fall of external signal
Fall of external start signal (EXTSTART1)
SC connector
Start signal from synchronization control connector
Generating
stop trigger
Software
Software command
Rise of external signal
Rise of external stop signal (EXTSTOP1)
Fall of external signal
Fall of external stop signal (EXTSTOP1)
Specified number of times Termination when the specified number of items is reached
SC connector
Stop signal from synchronization control connector
Bus master transfer error When FIFO buffer becomes empty
-
The product outputs the first pattern data at the falling edge of the generating clock signal after
input of the generating start trigger. From then on, the product outputs pattern data in
synchronization with the generating clock signal.
-
The product stops pattern data output upon input of the generating stop trigger.