3. Setup
22
DAI12-4(USB)GY
Connection Method
When connecting the module to an external device, you can use the
supplied connector plug. When wiring the module, strip off
approximately 7 - 8 mm of the covering for the cable, and insert the
bare wire by pressing the orange button on the connector plug.
Releasing the orange button after the wire is inserted fixes the cable.
Compatible wires are AWG 28 - 20.
Removing the connector plug by grasping the cable can break the
wire.
Figure 3.4. Connecting an Interface Connector and Connectors
That Can Be Used
CAUTION
Press this section to insert the wire
.
Connector used
2.5mm pitch, 12-pin type, 4.0A nominal current
MC0, 5/12-0, 25 [made by Phoenix Contact]
Compatible plug:
FK-MC0, 5/12-ST-2, 5 [made by Phoenix Contact]
Compatible cable: AWG28 - 20