M2M Gateway Basic Settings
—
M2M Gateway PLC Communication Settings
—
14
—
1.
Basic Operation
The following instructions concisely describe how to access the CONPROSYS for the communication
settings.
For setting the CONPROSYS, access the web server operated with the CONPROSYS controller and
perform the configuration.
Refer to the "Setup Manual" or "Reference Manual (Software)" for details on web access.
See the summary below for accessing procedure.
To run the CONPROSYS, the basic settings and operations listed below need to be completed.
The settings to use PLC information are explained in the following chapters.
- Network Settings
- Time Synchronization Settings
- Saving the Settings
---Notice---
Using LAN ports differs depending on the M2M Gateway models.
-
CPS-MG341-ADSC1-111, PS-MG341G-ADSC1-111
Two LAN ports within the product are recognized as one form OS with the same IP address.
-
CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-930 (Models with OPC UA server)
Two LAN ports within the product can be used with differing segment IP addresses.
The default IP address (10.1.1.101) used to access the M2M Gateway controller for the first time
is provided to the left-side LAN port. Connect the cable to the LAN port on the left.
Use the left-side LAN port to access for the first time.
Setting example for a PC and
the net
IP address : 10.1.1.200
Subnet mask: 255.0.0.0
Controller default info
IP address
:
10.1.1.101
Subnet mask
:
255.0.0.0
Build the environment in which the controller
and your PC can be connected to access
through a web browser.
The following is the default user information
for accessing.
User : mc341
Password : mc341