4. Functions
42
CNT-3204MT-LPE
Asynchronous Clear
When incremental counting in the CW (clockwise) direction is set with phase-Z positive logic, the board
clears the counter when the phase-Z input goes high while phases A and B are in the input state.
The board starts counting at the rising edge of the phase-A signal while phase-Z in the input state.
* When incremental counting in the CW direction is set with phase-Z positive logic, the board performs decremental
counting at the rising edge of the phase-A signal while the phase-B input remains low. When phase-Z negative logic
is used, the signal is enabled while the phase-Z input remains low.
Figure 4.6. Example counting during asynchronous clear
Phase-Z/CLR Input
Phase-Z is the signal to clear the counter to zero. The number of phase-Z inputs can be specified by
software.
Figure 4.7. Phase-Z enable frequency (Positive logic)
-
The initial setting is “only the next phase-Z input is enabled once”.
-
Phase-Z (negative logic) is enabled while the phase-Z input goes low.
-
When the phase-Z/CLR input is not used, be sure to disable the phase-Z input.
2
3
1
1
0
Phase-A
(Phase-A/UP)
Phase-B
(Phase-B/DOWN)
Phase-Z
(Phase-Z/CLR)
Count value
Phase-Z input
Disable phase-Z input
Counter 0 Ignored
Phase-Z input
Enable the next phase-Z input only once
Counter 0
0
Start
Phase-Z input
Enable every phase-Z input
Counter 0
0
Start
0
0
0
Ignored
Ignored
Ignored
Ignored
Ignored
Ignored
CAUTION
Содержание CNT-3204MT-LPE
Страница 7: ...vi CNT 3204MT LPE ...
Страница 15: ...1 Before Using the Product 8 CNT 3204MT LPE ...
Страница 29: ...2 Setup 22 CNT 3204MT LPE 3 Click on the End button to finish condition setting Click on End ...
Страница 45: ...3 External Connection 38 CNT 3204MT LPE ...
Страница 69: ...4 Functions 62 CNT 3204MT LPE ...
Страница 73: ...5 About Software 66 CNT 3204MT LPE ...
Страница 78: ......