2. System Reference
BX-2x0-DCxxxx, BX-2x0D-DCxxxx User’s manual
9
Table 2.2. Installation Environment Requirements
Model
BX-2x0-DCxxxx, BX-2x0D-DCxxxx
Operating temperature
*4
0 - 50
°
C
(When using 1000BASE-T : 0 - 45
°
C) *4
Storage temperature
-10 - 60
°
C
Humidity
10 - 90%RH (No condensation)
Floating dust particles
Not to be excessive
Corrosive gases
None
Line noise
AC line /
±
2kV *5,
Signal line /
±
1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Line-noise
resistance
Static
electricity
resistance
Contact discharge /
±
4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Atmospheric discharge /
±
8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
Vibration
resistance
Sweep
resistance
10 - 57Hz/semi-amplitude 0.375 mm 57 - 500Hz/5.0G
60 min. each in x, y, and z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Impact resistance
100G, half-sine shock for 6 ms in x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Ambient
specifications
Grounding
Class D grounding, SG-FG / continuity
*4 : For more details on this, please refer to chapter 3, “Installation Requirements”.
*5 : When AC adapter “IPC-ACAP12-04” is used.
Power Management Features
-
Support both ACPI (Advanced Configuration and Power Interface) and legacy (APM) power
management.
-
ACPI v2.0 compliant
-
APM v1.2 compliant
-
Hardware automatic wake-up
Содержание bx200 SERIES
Страница 1: ...IPC Series BOX PC for BX200 Series User s Manual CONTEC CO LTD ...
Страница 7: ...vi BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...
Страница 19: ...2 System Reference 12 BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...
Страница 27: ...3 Hardware Setup 20 BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...
Страница 51: ...4 Each Component Function 44 BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...
Страница 91: ...5 BIOS Setup 84 BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...
Страница 113: ...6 Appendix 106 BX 2x0 DCxxxx BX 2x0D DCxxxx User s manual ...