Consort PLC050/NC/TI(SS) Скачать руководство пользователя страница 1

 

66000059 Iss 07 

 

 

 

 

 

M

ILLIMETRES

 

 

W

ATTS

 A 

PLC050/NC/TI(SS) 500  442  430 196  123 
PLC075/NC/TI(SS) 750  442  430 196  123 
PLC100/NC/TI(SS 1000  614  430  364  125 
PLC125/NC/TI(SS) 1250  614  430  364  125 
PLC150/NC/TI 1500 

680 

430 

448 

116 

PLC150/NC/TISS 1400  680 430 448 116 
PLC200/NC/TI(SS) 2000  852  430  616  118 

 

 

M

ODELS

 

PLC050/SS PLC050TI/SS 

PLC050NC/SS 

PLC075/SS PLC075TI/SS 

PLC075NC/SS 

PLC100/SS PLC100TI/SS 

PLC100NC/SS 

PLC125/SS PLC125TI/SS 

PLC125NC/SS 

PLC150/SS PLC150TI/SS 

PLC150NC/SS 

PLC200/SS PLC200TI/SS 

PLC200NC/SS 

C

ONTR

O

LS

 

 

When the appliance is connected to the mains supply and the wall socket is switched ‘ON’ the mains neon indicator will light,

 showing 

that the power is available to the unit

.

 

The controls (except NC models) are located behind a cover on the 

right hand end of the appliance. 

 

The heaters (except the NC models) are fitted with a build-in 

thermostat to control the temperature level to which the room is heated.  
The thermostat adjustment knob is located on the right hand end and is 
numbered.  Rotate the knob clockwise to a higher number against the 
thermostat reference mark to raise the room temperature.  Once set it is 
unlikely to require being touched again. 
 

To set the heater to the Frost Watch mode, turn the thermostat 

control knob fully anti-clockwise until the frost symbol aligns with mark. 

 

U

SING THE 

T

IMER 

(TI Models only) 

 

The heater must be connected to the mains supply in order for the 

timer to operate continuously. 
 

Set the current time of day onto the timer by rotating the dial face 

clockwise until the correct time is indicated against the timer reference 
mark on the 24-hour clock face.

 

 

A

UTOMATIC 

O

PERATION

 

Move the switch immediately beneath the timer to the auto position 
designated       . 
1.

 

The 24-hour timer can be set to give any combination of On/Off 
intervals to a minimum of 20 minutes on.  Select the ‘On’ time 
required by pressing the black segment (on the circumference of the 
timer) adjacent to the time required outwards.  This will cause the 
heater to switch ‘On’ at the selected time for 20 minutes operation.  
Each additional segment pressed out will give a further 20 minutes of 
operation.  In this way, select the length of time required for the unit 
to be ‘On’ and push out the number of 20-minute segments necessary 
to select the time period required. 

2.

 

The timer can be set to give as many ‘On’ periods as required during 
any 24-hour period. 

3.

 

This program will repeat itself every 24 hours until changed.  This 
program may be overridden at any time by switching to manual 
operation. 

 

M

ANUAL 

O

PERATION

 

 

Move the rocker switch immediately beneath timer to the manual 

position designated     .  The heater will now run continuously, controlled 
by the heat settings and thermostat as described under ‘Controls’. 
 

 

T

HERMAL 

O

PERATED 

C

UT

-

OUT

 

 

The appliance is fitted with an Electronic Safety Control (ES).  This is a safety device, which switches the heater off if, for any reason, 

the appliance overheats.  The ES control can only be re-set after the appliance has cooled down.  In order to re-set the ES control, proceed as 
follows: 

 

Switch off appliance and leave for approximately 5 minutes. 

 

Switch appliance back on and ES control will re-set. 

 

Ensure that the appliance is functioning correctly.  If the ES control operates again, the appliance should be checked by a competent 
electrician. 

 

The heater carries a ‘Do Not Cover’ label to warn the user that if the appliance is covered, there is a risk of overheating. 

CAUTION – In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied through an 
external timer or connected to a circuit that is regularly switched on and off by the utility. 

 

M

OUNTING

 

This unit is for wall mounting only;

 

the wall bracket supplied must be used. 

1.

 

Remove wall bracket from the heater, with the chains attached, by removing the 2 securing screws from the top of the rear panel. 

2.

 

Fix wall bracket to wall using screw holes (4 off) provided. 

3.

 

Fig 1:  Present heater to bracket 

4.

 

Fig 2:  Locate heater onto bottom lugs via 2 sets of relevant slots in rear panel.  Hinge heater upwards and replace screws with  
  

link plates of chain attached, then move heater to upright position.  The link plates should slide under the slotted bracket lip. 

5.

 

Fig 3:  Tighten both retaining screws. 

The heater must not be located immediately below a fixed socket outlet. 

Thermostat 

and 

Switches

 

Thermostat 

Switches 

and Timer 

No 

Controls

  

m

Selector 
Switch 

Thermostat 
adjustment 
knob 

Heat Switches 
(Each gives half 
heat, both 
depressed – full 
heat) 

Timer 
reference 
mark 

Thermostat 
reference 
mark 

 
NB:  On the non-timer models there is  
no timer control and selector switch. 

Отзывы: