MECHANICAL INSTALLATION DIAGRAM

SHOWING BY PASS

Caution:

i) Do not store chlorine near or in the same room as heater.

ii) Valves must not be installed in the piping on the 

outlet of heater to the pool

/spa.

iii) Use PVC cement for connecting leakage current collectors 

into tank body and use teflon tape as sealer in the threads 
for drain plug.

d) Water 

Flow

The water flow in GPM should not exceed the following limits:

Table 01

Important:

Systems with higher GPM ratings will require a bypass around Heater.
This would be necessary if a high velocity pump is employed in the system.

Recommended:

Add water softener for longer heater life.

3

6

Heater

GPM

     K-5  

    08 (Max)

      K-10

      10

K-15

10

2.

Apply electric power to the heater, then rotate the thermostat
control clockwise to  the max. position.

The red indication lamp will be lit when the heater is on.

3.

After the desired temperature is reached, re-adjust the thermostat
control to suit your requirement.

The scale ranges from 70 to 110F.

4

A high limit manual reset thermostat is provided as a secondary back up 
high temperature limit protection. The reset thermostat may trip if the 
pump is switched off, or the heater chamber has too much air locked in it.
To reset, switch the heater breaker off. Allow the heater to cool and then 
depress the reset, as shown in Figure 05.

Winterizing:

For maximum security, first turn the thermostat to the off position and switch
off the electric power at the circuit breaker. Then completely empty the tank 
by removing the drain plug located at the bottom of the heater body. Drain
plug must be left out all winter. Cover the control panel of the heater with 
ordinary plastic cover to prevent any penetration of moisture or water into
electrical components. At all times the unit must be properly ventilated 
to avoid condensati

on.

FIGURE 05

WIRING DIAGRAMS (below)