11.4.7  Student mode

Navigate and set:  

System > OK > Student mode > OK > OK > Yes/No > OK

In this mode, stick input is directly sent to the trainer’s transmitter and all student settings 
are bypassed. When the »Transmitter operates in student mode it must not be connected 
to any receiver. Follow the on-screen instructions to enable and disable the student mode.

11.4.8  Timer settings

The »Transmitter is equipped with a timer and counter function.

11.4.8.1  Timer

Navigate and set:  

System > OK > Timer Setting > OK > Timer > OK > UP/DOWN > OK (hold)

 

>

Start timer:

 Press the key 

UP

 or 

DOWN

 until “Start” is displayed. Press and hold the key 

OK

 to confirm the input and start the timer. 

 

>

Cancel timer:

 Press the key 

UP

 or 

DOWN

 until “Stop” is displayed. Press and hold the 

key 

OK

 to confirm the input and cancel the timer. At this stage, even after leaving the 

menu, the time is preserved and you may restart the timer anytime. If you wish to reset 
the time, press and hold the key

 CANCEL

 after cancelling the timer.

11.4.8.2  Counter

Navigate and set: 

System > OK > Timer Setting > OK > Counter > OK > UP/DOWN > OK >... 
> OK (hold)

1.  Select counting mode: For the timer to count up set it to “Up” and to count down to 

“Down”. Press the key 

OK

 to confirm the input.

2.  Set the counter time (max. 60 minutes) with the keys 

UP

 and 

DOWN

. Press the key 

OK

 to confirm the input.

3.  Press the key 

UP

 or 

DOWN

 until “Start” is displayed. Press and hold the key 

OK

 to 

start the timer.

4.  When the preset time, depending on your settings, is reached or elapses, an audible 

alarm is emitted for a short time. Press and hold the key 

CANCEL

 to reset the time. 

 

>

If you wish to prematurely cancel the counter, set “Start/Stop” to “Stop” and press and 
hold the key 

OK

 to cancel the counter. At this stage, even after leaving the menu, the 

time is preserved and you may restart the counter anytime.

 

>

While the counter is running you can cancel the counter and reset the time at the same 
time by pressing and holding the key 

CANCEL

.

11.4.9  Alarm settings

The »Transmitter is equipped with an audible alarm function that notifies you after a preset 

time elapses, during which no switch, stick or key input was detected. 

Navigate and set: 

System > OK > Alarm Setting > OK > UP/DOWN > OK (hold)

1.  Set the alarm time (1 to 10 min.).
2.  Press and hold the key 

OK

 to confirm the input.

 

>

Any switch, stick or key input restarts the counter.

 

>

Any switch, stick or key input cancels the alarm and restarts the counter.

11.4.10 Firmware version

Navigate and set:  

System > OK > Firmware ver. > OK/CANCEL

The screen displays version and compilation date of the installed firmware.

Содержание 89102RC

Страница 1: ...89102RC Operating instructions M2 RC Logger R8 Radio System VRA VRB SWA 1 2 SWD 1 2 SWA 1 2 UP DOWN OK CANCEL POWER SWC 1 2 3 SWB 1 2 3...

Страница 2: ...2...

Страница 3: ...1 TRANSMITTER 11 11 1 Batteries 11 11 2 Basic functions 11 11 2 1 Turning the transmitter on and off 11 11 2 2 Home screen 12 11 2 3 Main menu 12 11 2 4 Backlight 13 11 2 5 LCD brightness 13 11 3 Tele...

Страница 4: ...arning 18 11 8 1 Auxiliary switch SWD 18 12 MAINTENANCE CARE AND REPAIR 19 12 1 Removing the throttle spring 19 13 DISPOSAL 22 13 1 General 22 13 2 Batteries 22 14 PRODUCT SUPPORT 22 15 TECHNICAL DATA...

Страница 5: ...rademarks of the respective owners All rights reserved We wish you a great deal of enjoyment with your new RC Logger product From here onwards the RC Logger R8 Radio transmitter is simply referred to...

Страница 6: ...ety GREEN also stands for good practice protecting your product from damage 6 INTENDED USE Use the Transmitter to control the NovaX 350 model quad copter for which it has been specifically designed Th...

Страница 7: ...on In case the Transmitter tips over the motors may accidentally start and the model take off Do not use the product during rainy weather or thunderstorms in wet conditions or when lightning is expect...

Страница 8: ...e protective gloves to handle corrupted batteries Batteries must be kept out of reach of children Do not leave batteries lying around There is a risk that children or pets swallow them All batteries s...

Страница 9: ...y switch 2 pos SWD 6 Right control stick 7 Right trims 8 Key OK 9 Key CANCEL 10 Power switch POWER 11 Battery compartment underside 12 LC Display 13 Neck strap attachment 14 Binding key 15 Key Down 16...

Страница 10: ...onnect the PPM cable from the Receiver Doing so eliminates the likelihood of the NovaX 350 inadvertently starting up 4 Turn the Transmitter off 5 Install the flight battery into the NovaX 350 6 Plug t...

Страница 11: ...n of the arrow and remove the compartment cover 3 Insert 4 new alkaline AA batteries into the battery recesses Mind the polarity indications 4 Close the battery compartment and make sure it locks prop...

Страница 12: ...Right trims s5 Left trims s6 Model name of selected model s7 Model number of selected model 11 2 3 Main menu MENU System setup Fig 5 The main menu Fig 5 is divided into two submenus System and Functi...

Страница 13: ...GPS reception status R T H status throttle timer bank settings AP Sport Custom mode To display telemetry data 1 Turn the Transmitter on 2 Press the key UP 16 3 Telemetry data is displayed 4 Press the...

Страница 14: ...r is below the preset value you will hear an audible alarm and the battery icon in the top tray of the display flashes High voltage When battery voltage is equal to the preset value it is considered f...

Страница 15: ...Press the key OK to confirm the input 2 Set the counter time max 60 minutes with the keys UP and DOWN Press the key OK to confirm the input 3 Press the key UP or DOWN until Start is displayed Press an...

Страница 16: ...gate and set System OK Factory reset OK OK UP DOWN OK This function will reset all Transmitter settings to their factory default values Important Note that all system and modes settings will be lost a...

Страница 17: ...ng direction 4 Set the other channels 5 To save and exit the end point settings press and hold the key OK 11 5 3 Display The Display screen Fig 9 displays the real time status upper and lower extent o...

Страница 18: ...nu or press the key CANCEL to exit without saving 11 6 Trimming For fine trimming or trimming during flight use the left 17 and right 7 trims Fine trim settings are displayed on the LC display Refer t...

Страница 19: ...e housing Mind the two cables that connect front and back Carefully unplug the cables from the PCBA see Fig 13 4 Place the transmitter on a wooden or similar block to prevent the sticks from touching...

Страница 20: ...20 Maintenance Care And Repair 4x 1 2 3 4 5 6 Fig 11 Fig 14 Fig 12 Fig 15 Fig 13 Fig 16...

Страница 21: ...Maintenance Care And Repair 21 4x 7 8 9 10 11 12 Fig 20 Fig 21 Fig 22 Fig 17 Fig 18 Fig 19...

Страница 22: ...or the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batteries rechargeable batteries free of charge to any collecting point of your local authority our stores...

Страница 23: ...7 FCC COMPLIANCE STATEMENT FCC ID Transmitter 2AARVRCL R8RADIO FCC ID Receiver 2AARVRCL RR8 TP Statement according to FCC part 15 19 This device complies with Part 15 of the FCC Rules Operation is sub...

Страница 24: ...24 www rclogger com...

Отзывы: