Quark Carrier
Users Guide
www.connecttech.com
Document: CTIM-00084
Revision: 0.04
Page 19 of 24
Date: 2020-12-15
THERMAL DETAILS
The Quark Carrier has an Operating Temperature Range of -25°C to +85°C.
However, it is important to note that the NVIDIA® Jetson
Nano™ / NVIDIA® Jetson Xavier™ NX Module
has its own properties separate to that of the Quark Carrier. The Quark is rated for Operating
Temperature Range of -25°C to +85°C.
Customer responsibility requires proper implementation of a thermal solution that maintains The Quark
SoC and Thermal Transfer Plate (TTP) temperatures below the specified temperatures (shown in the
tables below) under the maximum thermal load and system conditions for their use case.
NVIDIA® Jetson Nano™
Parameter
Value
Units
Maximum Tegra X1 Operating Temperature
T.cpu = 97
°C
T.gpu = 97.5
°C
Tegra X1 Shutdown Temperature
T.cpu = 102.5
°C
T.gpu = 103
°C
NVIDIA® Jetson Xavier™ NX
Parameter
Value
Units
Maximum Xavier SOC Operating Temperature
T.cpu = 90.5
°C
T.gpu = 91.5
°C
Xavier SOC Shutdown Temperature
T.cpu = 96.0
°C
T.gpu = 95.5
°C
CABLE INFORMATION
Drawing No.
Part No.
Function
Description
CBG112
Power Cable
6-pin MiniTek w/ Latch, unterminated
CBG117
Ethernet Cable 10-pin MiniTek w/ Latch, RJ-45 Panel Mount
CBG125
I/O Cable
DF20A 40 Pin, unterminated