Copyright
©
2016
congatec
AG
ICSLm13.indd
86/95
8.4.24
SDIO Configuration Submenu
Settings are displayed if an SD Card is connected.
8.4.25
Diagnostics Settings Submenu
Feature
Options
Description
POST Code Redirection Settings
Relay Interface
Disabled
I2C
SMBus
BC Diagnostics Console
Select the relay interface to which the POST code will be redirected.
Primary Port Addr. Lowbyte
(Dec)
0-255
(128)
Set the address for the primary debug port. The usual address value is 0x80 (i.e.
128 dec lowbyte and 0 highbyte). However, any multiple of 8 is valid for a primary
debug port address.
Primary Port Addr. Highbyte
(Dec)
0-255
(0)
Set the address for the primary debug port. The usual address value is 0x80 (i.e.
128 dec lowbyte and 0 highbyte). However, any multiple of 8 is valid for a primary
debug port address.
Relay Device Address (Dec)
0-255
(226)
Specify the I2C/SMBus device address of for example a 7-segment LCD for POST
code display. The factory settings for the SparkFun device is 0xE2(226). However,
any even device address can be specified.
BC Diagnostics Console Settings
Parity Bit
No Parity
Even Parity
Odd Parity
Choose the parity bits for the BC Diagnostic Console interface.
Stop Bits
1 Stop Bit
2 Stop Bits
Choose the stop bits for the BC Diagnostic Console interface.
Data Bits
5 Data Bits
6 Data Bits
7 Data Bits
8 Data Bits
Choose the data bits for the BC Diagnostic Console interface.
Baudrate
1200 Baud
2400 Baud
4800 Baud
9600 Baud
19200 Baud
38400 Baud
Choose the baudrate for the BC Diagnostic Console interface.