6.
Transport
ATTENTION!
The lifting unit must not be thrown or dropped during transport or installation.
The lifting unit must not be lifted by the power cable!
7.
Electrical connection
/
Observe the correct operating voltage (see “Technical Data“).
/
Never place the power plug in water.
/
Connect the lifting unit to a properly installed electrical socket (in compliance with VDE and the
power supply company regulations) protected by at least a 10 A (slow-blowing) fuse.
/
For units of protection classification I, all exposed conductive parts are connected with a protective
earth conductor. Before the unit is put into operation, an electrically skilled person must check that
the protective earth cable is properly connected.
/
Temperatures higher than those permitted cause the pump to be shut off by the temperature
limiter. After the temperature limiter is triggered, disconnect the pump from the electric system
before correcting the cause of the fault, otherwise it will switch on automatically once cooled down.
36
Содержание FLOW CUT BOX
Страница 25: ...20 Ersatzteile Abbildung 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 25...
Страница 49: ...20 Spare parts Figure 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 49...
Страница 73: ...20 Pi ces de rechange Illustration 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 73...
Страница 97: ...20 Reservedeler Figur 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 97...
Страница 121: ...20 N hradn d ly Obr zek 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 121...
Страница 145: ...20 P talkatr szek 16 bra 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 145...
Страница 169: ...20 Piezas de repuesto Figura 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 169...
Страница 171: ...171...