INSTALLATION
6.1
INSTALLATION DIMENSIONS
The the built-in rotary flange may be mounted in both horizontal and vertical pipes.
Fig. 3: Installation dimensions
Installation dimensions
CLEAR 2.0 RD 1½"
CLEAR 2.0 RD 2"
A: Fitting length with screw connection
301
335
A: Fitting length without screw connection
160
164
A1: Length on inlet side
175
195
B: Unit width
154
154
C: Height above pipe centre
207
207
D: Height below pipe centre
335
335
E: Depth to pipe centre
207
215
F: Waste water connection centre to pipe centre
118
126
G: Connection dimension waste water
50
50
G1: Connection dimension waste water (alternative) 13
13
All dimensions in [mm]