6.3.3.7
Mounting a section line feed
→
The section line feed is installed instead of a connector. Here, a different clamping part and a line feed cap with room for a
connecting cable to run out of it are used.
Fig. 107: Correct position of the clamping unit
Fig. 108: Incorrect position of the clamping unit
Fig. 109: Slightly loosen the screw connection with a screwdriver
(½ turn), locking the square nut to facilitate loosening if
necessary
Fig. 110: Slide the rail section into the free end of the section line feed as far
as the stopper
Fig. 111: Slide the line feed cover over the mounted connector
line feed
Fig. 112: Tighten the cylinder screw with 2 Nm