6.3.3.5.2
Mounting the expansion module with a setting aid
Requirements:
The conductor rail system is fully mounted up to the position of the expansion module.
The distance from the system edge to the last hanger clamp must be 125 mm. Move a hanger clamp if necessary (see Fig. 70).
If a hanger clamp must be moved or supplemented with another hanger clamp, the distance to the next hanger clamp must not
be greater than 500 mm
Fig. 70: Distance from the system edge to the last hanger clamp
If the setting aids are available (Pos. 1 Order No.: 08-S902-0002P), these must be inserted in each expansion gap of the expan-
sion module (Pos. 2) in such a way that they cannot be lost (see Fig. 71 to Fig. 72).
Fig. 71: Setting aids (Pos. 1) inserted in each expansion gap of the expansion module (Pos. 2)
1
2
1