6.3.3.1
Mounting the hanger clamps
The following must be observed when mounting the hanger clamps:
→
Set the hanger clamps at distances of approx. 500 mm and at distances of 400 mm and 250 mm respectively for inner and outer
horizontal bends. Mount the hanger clamps at a distance of 100 mm – 150 mm from the end cap (see Fig. 35).
→
At transfers and connection points, a minimum distance to end caps, connectors and expansion units of at least 200 mm must
be maintained. Here, the hanger clamps must be set so that hanger clamp collisions with other components of the system are
avoided during expansion of the system.
Hanger clamps are screwed or clipped into customer-specific guideway profiles. When mounting, ensure that the
pretensioning is not too great. Excessive pretensioning will distort the hanger clamp. There is a risk that the hanger clamp will no
longer rest flat on the central bar of the EMS rails.
Nevertheless, the hanger clamp must be seated firmly enough in its position that it cannot dislocate freely in the guideway profile.
Frequently, the hanger clamps only become firmly seated in the EMS rail when the conductor rails have been installed.
→
Provide additional fixing for clip-in hanger clamps that do not remain in their positions.
Fig. 34: Hanger clamp in EMS rail
Fig. 35: Distance of the hanger clamp
to the end cap