4.3
Description of the components
Fig. 4: Hanger clamp 0815
Hanger clamp 0815
Hanger clamps for supporting the conductor rail. The hanger
clamps listed in the catalog are screwable. In many cases,
customer-specific hanger clamps that are inserted in the sup-
port profile or are screwed into it are used. The conductor
rails slide into the hanger clamps longitudinally.
Fig. 5: Rail cross-section PH, PE and PE
plus
(with protection against
interchanging)
Fig. 6: PE
plus
principle
Fig. 7: Conductor rail
Conductor rail
Copper rail with PVC insulation as PH and PE as well as
PE
plus
rails can be supplied in 4000 mm and special 6000 mm
lengths on request. PE and PE
plus
rails are marked in
green/yellow. Phase rails are yellow.
Two protective conductor versions — PE and PE
plus
— are
available for the conductor rail system. For new systems, the
PE
plus
variant with protection against interchanging is used.
For PE
plus
rails, the insulation is opened wider for a broader
PE
plus
brush. The wider PE
plus
sliding contacts largely prevent
(without use of force or damage) the sliding contacts from
engaging in a phase rail. PE
plus
end caps are also wider open
and recognizable by their green color.
PH = Phase conductor
PE = Protective conductor
PE
plus
= Protective conductor with protection against inter-
changing