![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969115.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 115 of 128
10
Troubleshooting
WARNING!
Risk of injury due to improper troubleshooting!
Improper troubleshooting can result in serious injury to person and property.
→
Contact the manufacturer in case of malfunction.
→
Only allow troubleshooting to be conducted by personnel from or authorized by the manu-
facturer.
The faults that, to Conductix-Wampfler's best knowledge, tend to arise are listed in the following table (see Section 10.1) together
with their corresponding remedial measures.
Required protective equipment:
Requirement:
Faults must only be repaired by qualified personnel!
DANGER!
Risk of injury due to crushing skin and limbs!
There is a risk of crushing of skin and limbs due to:
Spring force/gravity (stored energy).
Current collector (spring force) during installation, disassembly and maintenance.
Be aware of the risk of falling conductor rail system components if they have not been properly
installed or if operated in inappropriate operating conditions (e.g., environment that contains sol-
vents).
Moving parts, when the system is in operation.
→
Do not enter the danger zones of the system during operation.
→
Only have installation conducted by trained technicians.
→
When working on the conductor rail system, wear protective footwear, protective gloves and a
protective headgear.
When changing the sliding contacts, follow the separate instructions for this task. See Section
12.1
→
Only install the conductor rail system where suitable operating conditions prevail. See Section 3.3.