![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969105.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 105 of 128
8.3
Stopping the system
Requirement:
DANGER!
Risk of injury due to electric shock!
→
Disconnect the conductor rail system from the power supply
according to the 5 Safety Rules
and
secure it against being switched back on
. For the 5 Safety Rules, see Section 2.5.
8.4
Continuing operation
WARNING!
Risk of injury if safety equipment and protective devices are disabled!
→
Before switching the system back on, ensure that all covers, safety systems and protective de-
vices are installed and working properly.
Before switching the system back on, ensure that:
The current collector heads are laying within the conductor rail for the entire length and the specified contact pressure must be
applied.
There is no heavy soiling or objects in the conductor rails.
→
Visually inspect the system.
The insulation resistance corresponds to the locally applicable technical guidelines.
→
Each time before the product or system is started, measure the insulation resistance according to locally applicable technical
standards, directives and legal regulations.
8.5
Perform regular maintenance and servicing
Perform regular maintenance and servicing in accordance with Section 9.
WARNING!
Risk of malfunctions!
Lack of maintenance and servicing can cause malfunctions and significant damage.