![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969104.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 104 of 128
DANGER!
Fire hazard due to overload or sparking!
Fire hazards occur due to overloaded cables, electrical arcs, short circuits or sparking. Sparking can
occur with poorly serviced, contaminated conductor rails or if the installation does not comply with the
required tolerances.
Take the following measures:
→
Conduct electrical testing as specified before commissioning.
→
Permissible current values must be observed.
→
Maintain tolerances during operation.
→
Do not remove the specified electrical safety devices and protective devices.
→
Do not store easily ignited materials near to conductor rails.
→
Inspect, service, and clean conductor rails regularly and in accordance with specifications see Sec-
tion 12.
→
Dimensioning according to permissible system load capacity and provide for appropriate electrical
protective devices.
WARNING!
Risk of injury due to hot components!
Components can get hot during operation.
→
Operation is only permitted in areas inaccessible to the public and out of manual reach.
→
The danger zone must be enclosed by the customer or protection ensured by distance.
→
Cordon off the work area.
→
Use caution when working in the vicinity of the danger zone, particularly if protective devices (co-
vers, enclosures, control devices) have been removed or disabled.
→
Wear personal protective equipment!
WARNING!
Risk of health issues due to respirable dust!
Airborne dust can cause respiratory complaints and eye irritation.
→
Clean regularly
→
One result may be cancer
8.2
Normal operation
The Conductor Rail System 0815 is protected against accidental contact and suitable for use in indoor operations, such as for electric
monorail systems (EMSs) or slip ring assemblies.
WARNING!
Only operate the conductor rail system in areas inaccessible to the public!
Operation is only permitted in areas inaccessible to the public and out of manual reach.
→
The danger zone must be enclosed by the customer or protection ensured by distance!