Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 30 of 82
Fig. 13: Current collector (dual collector)
Fig. 14: Current collector (single collector)
Current collector
Two divided carbon brushes guide the current collector on the Profi-
DAT
®
profile. The antennas are inserted into the slot in the ProfiDAT
®
profile and are electrically isolated from the carbon brushes.
Use of the single collector:
If there are no transitions in the traversing range
If there are no expansion joints in the system
With end infeed
4.3.2
Electrical Components
Fig. 15: Overview and arrangement of the electrical components
1
ProfiDAT
®
adapter cable
10 ProfiDAT
®
transceiver with 24 V power supply line
2
Infeed connection
11 R-SMA plug, terminating resistor 50 Ohm / 6 GHz / 1 W
3
Antenna adapter cable
12 N-connector terminating resistor, 50 Ohm / 6 GHz / 1 W
4
Antenna connection
A
Infeed switching cabinet
B
Current collector
C
Moving system part
D
ProfiDAT
®
profile
E
Expansion element (optional, depending on system type)