Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 24 of 82
Power supply/control voltage:
The controller of the ProfiDAT
®
data transmission system requires the following power supply:
Description
Voltage/frequency
AC power supply
Infeed switching cabinet
120–500 V, 50/60 Hz
DC control voltage
Transceiver
24 V DC*
* Deviations may occur, see the manufacturer’s documentation (chapter 11.2 “Other applicable Documents”)
WARNING!
Danger of injury by current collector!
Failure to comply with the prescribed supply voltages for the controller can cause a controller
failure and electrical components may be destroyed. As a result, the current collector may run
jerkily and hit persons or objects.
Observe and comply with the prescribed supply voltages.
Keep persons and objects out of the hazard area (see chapter
On commissioning of the transceiver devices, please observe that the cycle periods for the ProfiDAT
®
communication distances must
be adapted.
The cycle period must be at least 32 ms (but can differ depending on the application) and must be adjusted accordingly in the superior
control assembly group.
3.2.2
Mechanical
The interface between the data transmission system and the system is:
Current collector
The current collector on the ProfiDAT
®
profile performs a dual function. Two divided carbon brushes guide the current collector on
the ProfiDAT
®
profile. The carbon brushes secure the connection to the ground conductor rail (ProfiDAT
®
profile) while data
transmission occurs via the two built-in antennas. The antennas are inserted into the slot in the ProfiDAT
®
profile and are electrically
isolated from the carbon brushes.