2.7.3
Danger from dust and vapours
Required protective equipment:
DANGER!
Risk of sensitization, irritations of the mucous membranes and disorders of the respiratory
tract through dust!
Dust from the carbon brushes collects in the conductor rails and the guide profile. This dust is very
fine and is categorized as a health risk. Working a lot with the conductor rail system and/or not
applying the requisite level of care when handling accumulated dust (e.g. cleaning the system with
compressed air) can lead to sensitization. People that frequently spend long periods of time inside a
busy facility without protective equipment may be affected by the
following
:
Irritation of the mucous membranes
Diseases of the respiratory tract
Cancer
→
At workplaces that are continuously exposed, and also strongly frequented facilities, personnel must
be protected through effective measures against dust
→
Personal protective equipment must be worn during all works on the conductor rail system during
which accumulated dust is disturbed
→
The following personal protective equipment must be worn during cleaning operations:
Safety goggles
Dust mask class FFP3
Gloves
Disposable overall
→
Before starting work, clean the conductor rails according to regulations. See section 12.3
→
Protect the surroundings during cleaning work, for instance by covering or removing warehouse
goods and blocking access to those areas in which dust could fall down on persons
→
Remove dust with a vacuum cleaner.
Do not blow out dust with compressed air
Vacuum
cleaners should be fitted with a class H fine filter
→
Do not eat and/or drink while cleaning!
→
Do not smoke while cleaning!
DANGER!
Poisonous gases in case of fire!
In case of fire in the facility, the plastic parts (PVC) of the conductor rail system will generate
poisonous gases (HCL).
→
Evacuate the building immediately in the event of fire
→
Notify the fire brigade if there is a fire