4
Technical data
NOTE!
The data given in this chapter is valid only if the environmental conditions (nominal position, ambient
temperature, etc.) are complied with.
For example, deviations in the environmental conditions of the IPT
®
tracks, such as nominal position and
ambient temperature at the pickup, may lead to a reduction in output peak and continuous output power
or other variations. As a rule, an attempt should be made to guide the device to the nominal position with
a tolerance of ±20 mm and, if possible, not to swing the device too far out of the area of the field around
the track cables.
4.1
Electrical data
Input
IPT
®
track: 125 A 20 kHz, conductor distance 100 mm
Output voltage
27 V DC ± 7%
Maximum output current
27.8 A DC
Output peak power
750 W 40% ED*
Output continuous power
450 W @ min. 24V DC
(IPT
®
track: 125 A)
-
at 20°C ambient temperature
-
averaged over a period of 10 minutes
-
with an air flow of min. 0.1 m/s in nominal position
300 W @ min. 24V DC
-
at 40°C ambient temperature
-
averaged over a period of 10 minutes
-
with an air flow of min. 0.1 m/s in nominal position
Power loss
<50 W at full load
Electrical protection
Class II (reinforced insulation)
Insulation to ground
Output to ground tested at 3.7 kV DC/10 sec.
EN 50178
Max. current isolated 24 V
150 mA (not suitable for external users)
Supply (interface connector)
Standby consumption
approx. 10 W (switched on) or approx. 5 W (switched off)
(without load)
*max. 4 minutes (see chapter 7.4 and 8.3)