background image

Presented By

Dallas

Houston

Austin

Ft Worth

NicolScales.com

800.225.8181

Contact Us

Nicol Scales & Measurement is an ISO Accredited Calibration 

Company that has provided calibration, repair and sales of all types 

of weighing and measurement products since 1931.

Содержание Source 3000

Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...65546 Source 3000 Self Contained Pressure Source Console Operation and Maintenance Manual...

Страница 3: ...2 Source 3000 Operation and Maintenance Manual...

Страница 4: ...Removal 6 3 2 6 ORION 2C Manifold Vernier Control Disassembly 7 3 2 7 ORION 2C Manifold Vernier Control Reassembly 8 3 2 8 ORION 2C Manifold Valve Seat Installation 8 3 2 9 ORION 2C Manifold Panel Ins...

Страница 5: ...ii Source 3000 Operation and Maintenance Manual...

Страница 6: ...uced through negligent handling or operation of the console due to the high pressure cylinder contained within the unit These units are strictly for use with pneumatic pressures Erroneous readings and...

Страница 7: ...urce 3000 is designed for compatibility with all major manufacturer s electronic calibration equipment The following schematic provides an overview of the Source 3000 s function Figure 1 1 Source 3000...

Страница 8: ...4 Slowly open the valve on the nitrogen source and allow the gas to flow into the pressure cylinder NOTE Inlet check valve could be damaged if pressure is released too fast The SUPPLY PRESSURE gage 6...

Страница 9: ...port and the other end to the unit under test Tighten all connections properly NOTE If using a tee type port test hose connection the electronic standard is connected between the port and unit under...

Страница 10: ...ested and re certified every five years from date cylinder was manufactured per U S DOT 3AL Regulation Title 49 CFR parts 173 and 178 Tools required 7 16 wrench Phillips screwdriver 1 1 8 wrench 3 8 w...

Страница 11: ...required Phillips screwdriver 11 32 wrench or nutdriver 061 hex wrench adjusting screwdriver small flat blade 11 32 wrench thin 7 16 wrench NOTE See Table 3 2 on page 13 and Figure 3 3 on page 15 for...

Страница 12: ...tap steady and perpendicular to the seat slowly turn until the tap starts to engage the seat 13 When the tap has engaged into the seat use a small hammer and gently knock upward against the tap handl...

Страница 13: ...tighten until snug 3 2 8 ORION 2C Manifold Valve Seat Installation Tools required needle nose pliers tube fluorinated Krytox grease PN 55593 No 43 drill A R solvent de natured alcohol hex wrench 061...

Страница 14: ...tubing sections from Port 1 fitting PN 65485 and Port 2 fitting PN 59833 on the Orion 2C using a 7 16 wrench 6 Install the tubing sections from the vent and pressure inlet fittings PN 59833 on the Ori...

Страница 15: ...nob Remove the knob by turning counter clockwise 5 Remove all tubing sections that connect to the regulator inlet and outlet fittings 6 Loosen the mounting collar in the panel rear using a 1 4 hex wre...

Страница 16: ...34 should be plugged in whenever the unit is not in use Note For simplest method apply fluorinated Krytox grease to the outside surface between sealing lip and end of mating quick disconnect fitting V...

Страница 17: ...nclosure as described in Section 3 2 1 on page 5 and carefully set on a bench top 3 Loosen and remove the tubing end nuts from the tee fitting PN 65386 4 Loosen and remove the input port fitting nut l...

Страница 18: ...direction flow arrow is pointing of check valve into the female elbow fitting and tighten until snug 3 Install the other end of the check valve into the male reducing adapter run tee assembly 4 Instal...

Страница 19: ...or Black 4 29 55573 O ring AS568A Dash No 117 Buna N Nitrile 70 Durometer Color Black 1 30 60633 Retainer Packing Backup Single Turn Tetrafluoroethylene 4 31 55570 Washer Backing 04 Thick Tetrafluoroe...

Страница 20: ...ce 15 Figure 3 3 Orion 2C Exploded View 15 32 20 12 42 41 OR 14 OR 42 41 29 13 27 17 25 2X 25 2X 23 2X 3 4 5 24 3X 33 34 2 1 10 11 8 30 27 31 28 9 7 31 28 9 7 8 30 27 19 6 18 26 2X 38 21 14 16 36 35 2...

Страница 21: ...stainless steel Fill Port Style 1 4 37 AN flare male Pressure Rating 3400 PSIG rated 3050 PSIG operating Material 316 series stainless steel Test Port Pressure Rating 5000 PSIG rated 3000 PSIG operat...

Страница 22: ...If a unit is found to be defective it may be returned to our repair facility at the following address CONDEC 3 SIMM LANE DOOR D UNIT 2A NEWTOWN CT 06470 ATTN PRESSURE PRODUCTS REPAIR LAB Each unit s I...

Страница 23: ...CONDEC 3 SIMM LANE DOOR D UNIT 2A NEWTOWN CT 06470 ATTN PRESSURE PRODUCTS REPAIR LAB TEL 888 295 8475 FAX 203 364 1556 or 715 234 6967 WEB SITE www 4condec com COMPANY NAME STREET CITY STATE ZIP TELEP...

Отзывы: