51
Maintenance
7.4.2 Removal and installation of the components of the Condair RH for maintenance
7.4.2.1 Removal and installation of the cover of the internal water system
1. Remove the steam cylinder according to the information in
2. Undo the two screws on the control compartment cover and remove the cover.
3. Use a flat-blade screwdriver to press in the two tabs that secure the cover of the internal water
system to the housing of the Condair RH. One tab is on the top and one is on the separating plate
of the control compartment.
4. Pull out the top of the cover, then lift the cover out of the humidifier housing.
2
3
4
The cover of the internal water system is
installed
in the reverse order of the removal. When installing,
make sure that the two tabs on the cover correctly snap into the slots in the housing.
Содержание RH 1.8