Cleaning the Fill Valve
The fill valve contains a water filter. Debris can restrict water going to the cylinder or the drain valve.
The frequency of cleaning the fill valve filter is dependent on supply water quality, and should be
performed at the end of each humidification season.
Note:
Cleaning the filter may be performed without removing the fill valve, but removal is
recommended.
1
2
4
3
5
6
7
8
Figure 11 - Internal Plumbing Components
1. Fill cup
2. Hose, fill valve - fill cup
3. Hose, fill cup - cylinder (via drain valve)
4. Hose, fill cup - drain pan (overflow)
5. Fill valve
6. Quick connect fitting
7. Filter, fill valve
8. Condensate return cap
Removing the fill valve:
1. Remove the cylinder and plumbing cover. Remove the spade connectors from the fill valve.
2. Twist off the quick connect fitting from the fill valve, and slide the fill valve towards the front
of humidifier, then lift the valve.
Cleaning the fill valve filter:
1. Remove the quick connect fitting from the fill valve and remove the fill valve filter using
needle-nosed pliers.
2. Rinse the filter with water then use a damp cloth or soft brush to clean the filter.
Do
NOT
use soap or harsh chemicals.
3. Return and secure the filter to the fill valve.
4. Re-attach the quick connect fitting by hand, and wrench-tighten 1/4-turn at the end.
5. Return the fill valve (if removed).
Condair RH
2594949_B_EN_2005_Condair-RH_OM
Maintenance | 21