Maintenance and Replacement of components
6.7
Resetting the maintenance counter
After completing the total system maintenance or after replacement of the silver cartridge, the correspond-
ing maintenance indication or maintenance counter, respectively must be reset. Proceed as follows to
reset the maintenance counter:
Network
09/01/2021
DL
07:00 pm
Menu
General
Maintenance
Features
Controls
09/01/2021
DL
07:00 pm
Home
Next Maintenance
1685 hr
Demand
Standby
0%
USB Data Logger
Reset
Update
Histories
Error Analyzer
09/01/2021
DL
07:00 pm
Maintenance
09/01/2021
DL
07:00 pm
1001
Password
1
2
3
4
5
6
7
8
9
0
****
Passwort:
"8808"
Ag-Ion Reset
Error/Warning Reset
Factory Reset
09/01/2021
DL
07:00 pm
Reset
09/01/2021
DL
07:00 pm
Ag-Ion Reset
Do you really want to continue?
Back
Continue
1. Select in the "Reset" submenu (Path: "Menu > Password: 8808 > Maintenance > Reset"). Then
select the corresponding reset function ("Maintenance Reset" or "Ag-Ion Reset").
Note
: The reset function "Maintenance Reset" only appears if the menu has been accessed with
the engineering password.
2. The reset confirmation dialog appears:
• Press the
<Continue>
button to reset the corresponding maintenance counter ("Maintenance
Reset" or "Ag-Ion Reset"). The maintenance counter and the maintenance indication are reset.
• Press the
<Back>
button if the maintenance work has not been completed and you want to abort
the reset procedure. The control unit returns to the "Reset" submenu.