background image

HAVELLS SYLVANIA EUROPE LTD
Avis Way Newhaven East Sussex BN9 0ED
www.havells-sylvania.com

MI/1469-C - 11

a

 edition - 04/2012

installation and maintenance sheet

aluna SP/100 

Features - meaning of the symbols shown on the label:

underwater model for submerged operation only minimal voltage halogen lamp 

100W max - 12V - 8.35A - GY6.35 axial filament
  

totally dust-proof

  IP68  10m  indefinite submerged operation - max allowed depth 10m
 

  mounting on normally inflammable surfaces allowed

 

   very low voltage feeding with security transformer 

  Class III  

  no earth required

  

 

  replace the damaged protective glass

 

  getting rid of as urban waste forbidden

 

  separate collection is mandatory 

 

  when the product is at the end of its life

glass features: plane float glass - safety tempered

Installation:

•  lamp feeding shall be by means of a security transformer (symbol     ), power not 

less than 100VA, output voltage 12V. The transformer shall be protected against 

overloading and short-circuit (see models single CT box (4068479) - double CT 

box (4068480)). The feeding cable must be neoprene rubber type H07RN8-F 

(EN  60598-2-18  CENELEC  HD  22.4),  of  minimum  section  2x1.5mm

2

.  The 

floodlight is supplied by us with the lamp already installed and connected with 

H07RN8-F cable of section 2x2.5mm

2

 in length 5.5 meters. The cable and the 

fixture must not be tampered with for any reason.

• Check carefully that the transformer power is sufficient.

•  max. installation depth 10m.

 

Relamping: 

• respect fully type and power of lamp as shown on the label.

Read  carefully  the  instructions  of  the  lamp  manufacturer  for  proper 

 

lamp  use.  The  relamping  must  be  done  with  maximum  attention 

 

avoiding to dirty the sealing gasket and its contact to surface. It is therefore 

necessary before opening the fixture to carefully wipe the floodlight 

then  unscrew  the  round  frame  by  the  proper  key  (code  4068469). 

 

If  the  gasket  is  damaged,  deformed  or  not  in  perfect  conditions 

 

it  is  necessary  to  change  it  with  the  one  enclosed  in  the  packing. 

 

(see figure)

 

Maintenance:

• it is essential to do a frequent cleaning of the glass and 

of the outer surface of the fixture to avoid build up of mud and dirtiness resulting 

in dangerous overheating due to obscured light and heat dissipation. Clean the 

glass screen carefully by removing limestone deposits by means of a scraper. 

N.B. the floodlight must be operated underwater.

 

 

Quality control: Should you have any complaint please get in touch with our 

company or its sales organization. Please give the number of your order as well 

as the serial number that recognizes the fixture.

119 

60 

75 

¯106 

¯140 

200 

90 

It is necessary to place the gasket exactly 

into its seat as shown  in the picture.  

Then screw on gently the frame and tighten 

it by the opening/closing key (4068469).

ET/0932

NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the lamp. The 

appliance must not be tampered with or transformed and it must be installed and used as supplied and in compliance with the National 

Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company cannot be held responsible for 

damage caused by incorrect assembly.

 IS13104

Отзывы: