INSTALLATION AND OPERATION INSTRUCTIONS

Certified ISO 9000

ADI  1098-P

Controls Corporation of America

1501 Harpers Road • Virginia Beach, VA 23454

To Order Call 1-800-225-0473 or 757-422-8330 • Fax 757-422-3125

www.concoa.com

Before Installing or Operating, Read and Comply with These Instructions

Gas Mizer

September  2001

Supersedes August  2000

Certified ISO 9000

Controls Corporation of America

1501 Harpers Road • Virginia Beach, VA 23454

To Order Call 1-800-225-0473 or 757-422-8330 • Fax 757-422-3125

www.concoa.com

ADI  1098-P

Содержание 65

Страница 1: ... Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com Before Installing or Operating Read and Comply with These Instructions Gas Mizer September 2001 Supersedes August 2000 ...

Страница 2: ...c or written request for service advice be made to the CONCOA Customer Service in Virginia Beach Virginia PHONE 1 800 225 0473 FAX 1 757 422 3125 E MAIL e mail concoa com Please be preapred to provide the model number and serial number of the equipment involved in addition to some details regarding its application Comply with all safety precautions given in torch instruction manual and the followi...

Страница 3: ...t off valves can be individually adjusted by their seat adjust ment screws This seat adjustment controls ignition by LEAD for ON and LAG for OFF SAFTEY Install pressure regulators on cylinders or pipline branch Comply with CONCOA manual Safe Practices in Welding Cutting ADE 872 and torch and regulator instruction manuals a Secure the Gas Mizer on a bench or other horizontal surface using four moun...

Страница 4: ...same pressure settings at each regulator as if this device were not in the torch system Hanger Rod Adjustment When placing the Mizer in operation the hanger rod should be adjusted so that the hand torch will shut off the fuel gas and oxygen valves with its own weight a Close the pilot valve by turning the pilot valve T handle clockwise until it stops Tighten only enough to ensure a tight seal b Wi...

Страница 5: ...rform repairs CAUTION Shut off gas supplies at source before attempting inspection or service unless leak testing with an approved oxygen compatible leak detection fluid General Servicing is usually required if gas escapes from the hand torch when it is on the hanger rod test by hand pressure on the hanger rod If the torch and station outlet valves are closed but the regulator indicates a slow cha...

Страница 6: ...nous basis the flow rate should be no more than 1 15 one fifteenth of the capacity of the cylin der per hour NOTE Check valves prevent the reverse flow of mixed gases Regulator Check Valves B size 830 4199 Oxygen 830 4200 Fuel Torch Check Valves B size 831 4146 Oxygen 831 4138 Fuel IMPORTANT For Maximum Safety Use Flashback Arrestors Regulator Mounted Regulator Mounted Torch Mounted Model 78 Reset...

Страница 7: ...therthanCONTROLSCOR PORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole and exclusive remedy under the above warranties is limited to repairing or replacing free of charge at CONTROLS CORPORATION OF AMERICA s option the equipment or part which is reported to its Authorized D...

Страница 8: ...Certified ISO 9000 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com ADI 1098 P ...