SPECIFICATION

CAUTION

 INSTALLATION

1.  This installation should be made by a qualified service person and should comply with all  

 

local regulations.

2.  In order to prevent electric shock and prevent damage to waterproof seals, do not loosen  

 

any screws on the camera body.

3.  Avoid installation on a surface subjected to frequent vibration or shocks.

4.  Do not operate the camera beyond its temperature range or power rating.

5.

 

Should any damage or suspected damage occur, shutdown the power source, unplug and  

 

contact your service provider.

6.  Do not install the camera under unstable lighting conditions. Severe lighting changes or  

 

flicker can cause the camera to work improperly.

7.  Never use the camera close to a gas or oil leak.

8.  Do not dismantle the camera.

9.  Do not install the camera facing directly into bright sunshine, this could damage the sensor.

10.  Ensure all removable covers are replaced to protect the inner components.

11.  Do not install near devices which emit a strong electro-magnetic field.

12.

 

Use a dry or damp cloth to clean the dome sphere.

13.  Do not drop the camera or subject the unit to physical shocks. 

 

PLEASE FOLLOW THE ABOVE PRECAUTIONS – FAILURE TO DO SO MAY  

 

 

INVALIDATE THE WARRANTY OR CAUSE SERIOUS INJURY.

Remark: Changes or modifications not expressly approved by the manufacturer can 

cause the camera to be damaged and become inoperable. This may invalidate the 

user warranty.

PACKING CONTENTS

Design and specification are subject to change without notice.

MODEL
SENSOR
SENSOR RESOLUTION
SIGNAL SYSTEM
SCANNING SYSTEM
SYNC. MODE
FRAME RATE
LED COUNT/TYPE
IR EFFECTIVE DISTANCE
EFFECTIVE RESOLUTION
MIN. ILLUMINATION (LED OFF)
MIN. ILLUMINATION (LED ON)
LENS
DAY & NIGHT
DIGITAL WDR
S/N RATIO
ELECTRONIC SHUTTER
WHITE BALANCE
GAIN
AE MODES
DIGITAL NOISE REDUCTION
PRIVACY MASKING
MOTION DETECTION
VIDEO OUTPUT
TRANSMISSION RANGE
SUPPLY VOLTAGE
POWER CONSUMPTION  (MAX)
OPERATING TEMPERATURE
OPERATING HUMIDITY
DIMENSIONS
WEIGHT
CERTIFICATIONS

CVP9314DNIR-AHD

1/3 INCH SONY CMOS

2MP
PAL

PROGRESSIVE

INTERNAL

25fps

2 PCS IR HIGH POWER

Up to 50m

1920(H)x1080(V)

0.001Lux @ (F1.2,AGC ON)

0 Lux 

2.8mm FIXED

TRUE COLOUR/MONO ICR

OFF/ON(Level 0-8)/Auto

≥50dB

1/50-1/50,000s

ATW/AWC-SET/Indoor/Outdoor/MANUAL

LEVEL 0-15

BLC/HLC/OFF

2D/3D

YES
YES

1.0Vpp, 75 OHM BNC

>300m via 75-5 coaxial cable

12VDC±10%

4.5W

MIN-25℃/MAX+55℃

90% RH MAX  (non-condensing)

ΦMAX119mm x ΦMIN109mm x H91mm

410g

IP66/IK6 /CE/FCC

118mm

109mm

CONNECTION

l

  Connect the video out port to your video cable  

  running to the monitor / recorder  

l

  Check the power supply is of the correct level  

  and connect your power supply into the power  

  port on the Camera. 

l

  View the picture on a monitoring device to  

  check the power and video connection are  

  working properly.

l

  To assist in installation when using an

  analogue test monitor, the camera can

  be switched to an analogue output by

  pushing the joystick fully left for several  

  seconds.

l

  The camera can be returned to AHD

  output by pushing the joystick fully

  right for several seconds.

PSU

Troubleshooting

l

 

Ensure all power and cable connections are correct with the Camera and DVR.

l

 

If all power and cable connections are correct and the camera picture can not be  

  produced then contact your supplier for technical support. 

Wall Plugs

X4

Conduit hole cover 

opener

X1

Mounting Template

X1

Fitting Screws

X4

Dome cover 

screwdriver

X1

Weatherproof 

sealing washers

X8

Weatherproof 

sealing pad

X1

 

 

 

c

 

 

 

14

Step 4: Adjust The Monitoring Direction

4) 

 

Install the dome shell and compression ring on the  

     camera mounting base. Adjust the camera      

    

     monitoring direction, then fix the screw to finish the     
     installation, as shown in Figure 4.

2

1

1a

1

1b

12

13

Step 1: Take Out The Compression Ring

1a)  

Open package, take out the camera, unscrew              

       the screw, and take out the compression ring, as     
       show in Figure 1a.

1b)

  

If the side cabling mode is used, cut open the          

       compression ring outlet as shown in Figure 1b.

Step 2: Drill Holes

2)  

 Stick the positioning label on the wall, and drill        

      holes based on the marks on the positioning label.     
      See Figure 2.

Step 3: Fix The Camera Mounting Base

3)  

 

Insert wall plugs into the drilled holes, and fix the             

      camera mounting base to the ceiling (or wall) with         
      self-tapping screws, as shown in Figure 3.

118mm

109mm

118mm

109mm

118mm

109mm

118mm

109mm

118mm

109mm

DIMENSIONS

b

 

 

 

All installation methods

Loosen the three tamper screws using the provided allen key. Lift the dome cover.

NOTE: If you plan to use conduit fitting, remove conduit cap using the provided conduit key. 

Method 1 - Surface Mount

Use the included mounting template (installation option 2) to mark and pre-drill the required holes. 

Remove 2 of the 3 base locking screws. Use 2pc of the 2.8” screws to mount the camera directly to 

the mounting surface.

Remove the 3rd base locking screw and install the 3rd 2.8” screw.

Method 2 - Surface Mount

2b. Use the included mounting template (installation 

Option 1) to mark and pre-drill the required holes.

2c. Remove the camera base by unscrewing the 3 base 

locking screws, and turn camera module approx. 5 

degrees counterclockwise to detatch camera base from 

the camera module.

2d. Install the base to the correct holes as indicated on 

the mount template using the 1.2” screws.

Go to step 3a to complete installation.

VANDAL RESISTANT DOME INSTALLATION