![Conair TrueBlend TB500-4 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/conair/trueblend-tb500-4/trueblend-tb500-4_user-manual_2649034070.webp)
Operation
TrueBlend
™
68
Edition: February 2007
7.8.3 Typical dispense cycle based (7.8.2) settings
1st Step:
regrind is metered
regrind 20% of total weight = 200 g
2nd Step:
Natural material is calculated
as 100% of the balance of batch = 686 g
(automatically calculated/metered)
3rd Step:
additive natural is metered
(Color) 2% of N = 13.7 g
(automatically calculated/metered)
4th Step:
additive batch is metered
10% of total weight = 100 g
(automatically calculated/metered)
The controller must be set to match this sequence.
The percentage of natural material is
automatically calculated
by the controller.
[Sum of Natural(s) material = 100 %].
The percentages of the additive naturals are
always
based on the natural(s)
material.
The percentages of the additive batch is
always
based on the entire batch and
therefore are metered last.