Maintenance and Repair
TrueBlend
™
132
Edition: February 2007
Î
To complete the installation of the load cell it is necessary after installation to
pre-stress the load cells. This can be performed in two ways - either by
hanging a 10 kg weight onto one load cell or re-installing the weigh bin and
placing a 20 kg weight into the bin. This weight should stay in place for ten
seconds and then removed. Repeat this procedure three times.
Î
Do an empty and full calibration (see manual) and operate as normal.
9.6.5 Replacing
controller
Determining blender model
See 7.7.3 Input TrueBlend Model. After installing new controller, verify that the
blender model designated on the control matches the model number of the
blender it is connected to.
Fig 22
1
2
3
4
5
6
Gap .005“
Gap .020 inch
Alternatively set at 0 inches when
weigh bin is loaded with 20 kg
7
8
9
Содержание TrueBlend TB500-4