4. FOLLOW ME:
The control unit allows the “Follow me” function to be configured; programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 1 second after freeing the DS1 photocell, meaning the barrier re-closes 1 second after transit of the user.
If you wish to enable this function proceed as follows: ensure you have enabled Extended Menu 2 (flashing 1 1 0 1 1 0 of LED LEV) and
then use the SEL key to select flashing LED L4 and press the SET key; LED L4 becomes steady on and programming will be completed.
Repeat the operation to restore the previous configuration.
5. PRE-FLASHING:
The control unit is factory set with the Preflashing function disabled. If you wish to enable the Preflashing function, proceed as follows:
ensure you have enabled Extended Menu 2 (flashing 1 1 0 1 1 0 1 0 of LED LEV) and then use the SEL key to select flashing LED L5 and
press the SET key; LED L5 becomes steady on and programming will be completed; in this manner the flashing light output will always
switch on 3 seconds before the barrier starts moving. Repeat the operation if you want to restore the initial configuration.
6. NOT USED
7. NOT USED
EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed as follows: position the LEV LED flashing and press SET 3
times. The LED will start flashing alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a period of 30 seconds to select the functions in
Extended Menu 3 using the SEL and SET keys and then, after a further 30 seconds, the control unit will revert to the main menu.
level
LED ON
L1
1
LED 1
L2
2
LED 1 +LED 2
L3
3
LED 1 +LED 2 +LED 3
L4
4
LED 1 + LED 2 +LED 3 +LED 4
L5
5
LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6
6
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7
7
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV
Menu
3 Flashes
DECELERATION SPEED ADJUSTMENT:
The motor speed during the deceleration stage can be programmed on the control unit.
It is possible to choose between 7 different power levels in this way: make sure you have enabled the Extended Menu 3, each combination
of lit LEDs corresponds to a level according to the table above; in practice, starting from the lowest LED (LED L1) and going upwards each
LED corresponds to a higher power level. Using the SEL key, it is possible to scroll through the different power levels; for each power level
selected, the respective uppermost LED flashes (for example if level 4 is selected, LEDs L1 + LED L2 + LED L3 are steady on, while LED
L4 flashes); press SET to confirm.
Factory setting: level 3 selected.
12 RESET
If you need to reset the control unit to restore the factory settings, press the SEL and SET keys together; this will cause all the RED indicator
LEDs to light simultaneously followed immediately by the control unit switching off.
CAUTION:
When the control unit is powered (and the power is restored), the FW version is revealed with the brief activation of a fixed
number of LEDs in the main menu (for example, the first 2 LEDs lit for 0.5 seconds = FW rev.02). This information can be useful for the
technical assistance service.
CAUTION:
restoring factory settings does not include deletion of all previously saved Remotes and resetting of the first remote rule logic.
13 DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle, a functional test of the connected photocell is performed. In the case of an open circuit and/or malfunctioning of the photocell, the
control unit does not enable movement of the barrier and visually signals the test failed condition by causing all the indicator LEDs to flash
simultaneously. As soon as correct operation of the photocell is restored, the control unit is ready for normal use. This operating mode
guarantees fault monitoring in compliance with EN 954-1 Category 2.
Command input test:
With each low voltage command input, the control unit has a signalling LED in order to be able to quickly check the status. Operating logic:
LED on, input closed, LED off, input open.
Содержание BORDER 400
Страница 3: ...3 COMUNELLO Copyright 2020 All rights reserved FIG 4 FIG 5 FIG 6 FIG 7...
Страница 4: ...4 COMUNELLO Copyright 2020 All rights reserved FIG 8A FIG 8B FIG 8C FIG 8D...
Страница 5: ...5 COMUNELLO Copyright 2020 All rights reserved FIG 9A FIG 9B FIG 10A FIG 10B...
Страница 6: ...6 COMUNELLO Copyright 2020 All rights reserved FIG 11A FIG 11C FIG 11B FIG 12A FIG 12B FIG 12C...
Страница 7: ...7 COMUNELLO Copyright 2020 All rights reserved FIG 13A FIG 14 FIG 13B...
Страница 8: ...8 COMUNELLO Copyright 2020 All rights reserved FIG 15 FIG 16 A FIG 16 B A...
Страница 9: ...9 COMUNELLO Copyright 2020 All rights reserved FIG 17A FIG 17B FIG 17C FIG 17D...
Страница 10: ...FIG 18 A B 100mm 200mm 200mm FIG 19...