33
COMUNELLO
®Copyright 2020 - All rights reserved
ENGLISH
1. REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely without acting directly on the control unit SEL key.
Remote programming of a Radio remote control is performed as follows: send the code of a previously saved remote continuously for
more than 10 seconds; at the same time the control unit switches to programming mode as described above for LED L1 in the main
menu. To enable the remote programming function, proceed as follows: make sure you have enabled the Extended Menu 1 (alternating
flashing 1 0 1 0 1 0 of the LEV LED)), use the SEL key to position the LED L1 flashing and then press the SET key: LED L1 will switch on
permanently and programming will be completed. Repeat the operation if you want to restore the initial configuration.
2. OPENING DIRECTION (DIR):
The control unit in the default configuration has the “LEFT ARM” logic (Fig.10B); if it is necessary to enable the "RIGHT ARM" logic (Fig.
10A), proceed as follows: use the SELECT key to position LED L1 flashing and press the
SET
key: LED L1 will switch on permanently and
programming will be completed. Repeat the operation to restore the previous configuration.
WARNING:
if it is necessary to invert the opening direction, invert the FCA and FCC cables.
3. AUTOMATIC PROGRAMMING:
The control unit is used to perform Automatic Programming (SIMPLIFIED) in the following way: be sure to have positioned the open barrier at 45°
and to have enabled the extended menu 1 (highlighting the flashing 1 0 1 0 1 of LED no. 8), use the SEL key to select the 3rd flashing LED:pressing
continuously SET key, the control unit executes the AutoProgramming procedure by performing a complete opening and closing
Press SET to confirm. During Automatic Programming, it is possible to use the SET key on the control unit to stop the procedure if
necessary.
4. FOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled. If you wish to enable the photocells test proceed as follows: ensure you
have enabled Extended Menu 1 (flashing 1 0 1 0 1 of LED LEV) and then use the SEL key to select flashing LED L1 and press the SET
key; LED L1 becomes steady on and the operation will be completed. Repeat the operation to restore the previous configuration.
5. DS1 in opening:
The control unit allows to modify the operation of the opening DS1. If you want SAFE 1 to operate also during opening (momentary
stopping of the barrier, as soon as the photocell is freed the control unit resumes the opening movement), proceed as follows: ensure you
have enabled Extended Menu 2 and then press the SEL key to select flashing LED L3 and press the SET key: LED L3 becomes steady
on and programming will be completed.
Repeat the operation if you want to restore the initial configuration.
6. NOT USED
7. NOT USED
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main menu functions. To enable the functions described in
extended Menu 2, proceed as follows: select flashing LED LEV and press SET twice. The LED will start flashing alternately 1 1 0 1 1 0. This
means you have 30 seconds to select the functions of Extended Menu 2 using the SEL and SET keys; once an additional 30 seconds
have elapsed, the control unit reverts to the main menu.
LED OFF
LED ON
L1
DO NOT USE
DO NOT USE
DO NOT USE
L2
FLASH.OUT.CNTRL.
SIGNAL LIGHT
PERMANENT
L3
ALWAYS CLOSE
OFF
ON
L4
FOLLOW ME
OFF
ON
L5
PRE-FLASH
OFF
ON
L6
DO NOT USE
DO NOT USE
DO NOT USE
L7
DO NOT USE
DO NOT USE
DO NOT USE
LEV
MENU
2 FLASHING LIGHTS
1. NOT USED
2. 24V 4W MAX FLASHING LIGHT OUTPUT CONTROL:
The control unit is factory set with an intermittent output for connection to a 24V Flashing light (0.5 sec ON – 0.5 sec OFF). If you wish to
enable a fixed output, proceed as follows: ensure you have enabled Extended Menu 2 (flashing 1 1 0 1 1 0 1 0 of LED LEV) and then use
the SEL key to select flashing LED L2 and press the SET key; LED L2 becomes steady on and programming will be completed. Repeat
the operation to restore the previous configuration.
3. ALWAYS CLOSE:
The control unit provides the facility to set “Always Close” operation: this function, which is programmable only if a Pause Time has
already been programmed, is activated after a power loss; if the barrier open condition is detected, a closing movement will be started
automatically, preceded by 5 seconds of pre-flashing. If you wish to exclude this operating mode proceed as follows: ensure you have
enabled Extended Menu 2 (flashing 1 1 0 1 1 0 of LED LEV) and then use the SEL key to select flashing LED L3 and press the SET key;
LED L3 becomes steady on and the operation will be completed. Repeat the operation to restore the previous configuration.
Содержание BORDER 400
Страница 3: ...3 COMUNELLO Copyright 2020 All rights reserved FIG 4 FIG 5 FIG 6 FIG 7...
Страница 4: ...4 COMUNELLO Copyright 2020 All rights reserved FIG 8A FIG 8B FIG 8C FIG 8D...
Страница 5: ...5 COMUNELLO Copyright 2020 All rights reserved FIG 9A FIG 9B FIG 10A FIG 10B...
Страница 6: ...6 COMUNELLO Copyright 2020 All rights reserved FIG 11A FIG 11C FIG 11B FIG 12A FIG 12B FIG 12C...
Страница 7: ...7 COMUNELLO Copyright 2020 All rights reserved FIG 13A FIG 14 FIG 13B...
Страница 8: ...8 COMUNELLO Copyright 2020 All rights reserved FIG 15 FIG 16 A FIG 16 B A...
Страница 9: ...9 COMUNELLO Copyright 2020 All rights reserved FIG 17A FIG 17B FIG 17C FIG 17D...
Страница 10: ...FIG 18 A B 100mm 200mm 200mm FIG 19...