Configuration Using the Web User Interface
Network Redundancy | Redundant Ring Configuration Page
Use this page to create new Ring configurations and edit existing Ring configurations. Typically, managed
switches /routers are connected in series and the last switch is connected back to the first one. In such
connection, you can implement Redundant Ring technology.
To create a new ring ID, type a Ring ID and Name and select the characteristics from the table, click
Apply
when done.
Note:
You must
Save
) settings, if you want to maintain these settings if the WR7802-XT is rebooted.
Redundant Ring Configuration
Add New Ring:
Ring ID
Ring1 with an Ring ID of 1 is created by default and cannot be deleted.
The valid range is from 0 to 31 with a maximum 32 rings.
Name
Type the name of the Ring. If it is not filled in when creating, it is
automatically named Ring and the Ring ID number, for example: Ring2.
Priority
The switch with highest priority (highest value) is automatically selected
as the Ring Master. If all of the switches have the same priority, then the
switch with the highest MAC address is selected as the Ring Master.
Ring Port 1/ Ring
Port 2
In a Ring, two ports should be selected to be Ring Ports. For the Ring
Master, one of the ring ports becomes the forwarding port and the other
one becomes the blocking port.
Path Cost
Change the Path Cost of Ring Port. If this switch is the Ring Master of a
Ring, then it determines the blocking port. The Port with higher Path
Cost in the two ring ports becomes the blocking port, If the Path Cost is
the same, the port with larger port number becomes the blocking port.
Status
To enable/disable the Ring. Remember to enable the ring after you add it.
Select
Click the
Select
check box if you want to Edit or delete the selected row.
Beta