106 - RedBoot Procedures
DeviceMaster LT User Guide
: 2000586
Rev. B
Configuring Passwords
If uploading SocketServer
:
a.
At the RedBoot> prompt, type:
fis list
and press
Enter
.
Note:
You should see file information for a file called
default
. If you do not
see this file, repeat the process starting with
b.
Reset the DeviceMaster LT by typing
reset
at the RedBoot> prompt.
Note:
In a few seconds the ethernet and
Status
LED cycle through a light
sequence once.
c.
Start your internet browser and enter the IP address of the DeviceMaster
LT to verify that the new version of SocketServer loads.
Configuring Passwords
This section discusses how to configure a password for the web and telnet server.
Note:
See the PortVision DX or SocketServer Help system for information about
email notification.
Use the following procedure to establish the DeviceMaster LT password for the
Web and telnet server. Establishing a password prevents unauthorized changes to
the DeviceMaster LT configuration.
1.
Establish communications with the DeviceMaster LT using the serial (Page
100) or telnet method (Page 101).
2.
Type
password
[
your_password
] and press
Enter
.
Note:
If you forget your password, you can reprogram the password using the
serial method which bypasses the password.
Note:
The Bootloader version on your DeviceMaster LT may be different than
the version displayed in this graphic.
See the
auth
command in the
on Page 107, if you
want to set up Web browser authentication.
RedBoot>
fis list
Name
FLASH addr Mem addr Length
Entry point
FIS_directory 0x053F0000 0x053F0000 0x00010000 0x00000000
default
0x05030000 0x00000000 0x00090000 0x00000000
RedBoot>
Password:
*********************************************
**
** Comtrol DeviceMaster Bootloader Version 3.23
** RedBoot(tm) environment - built 14:59:20, Oct 13 2011
** Platform: Comtrol DeviceMaster (ARM 7TDMI)
** Portions Copyright (C) 2000. Red Hat, Inc.
** Portions Copyright (C) 2001-2008 Comtrol Corp.
*********************************************
FLASH: 64 blocks of 65536 bytes each
FLASH: 4194304 bytes (0x05000000 - 0x05400000)
RAM: 8126464 bytes (0x00000000 - 0x007c0000)
RedBoot>
dis
Loading disabled
RedBoot>
password
dev1357
Password ‘dev1357’
RedBoot
>