Comtrend Corporation GS-7608 Скачать руководство пользователя страница 1

 

 

 

 

 
 
 
 
 
 

5/8 Ports Gigabit Ethernet 

Smart-Lite (PoE) Switch

 

User Manual

 

GS-7608, 8-Port PoE Gigabit Ethernet Smart-Lite Switch 
GS-7605, 5-Port PoE Gigabit Ethernet Smart-Lite Switch 
GS-7408, 8-Port Gigabit Ethernet Smart-Lite Switch

 

GS-7405, 5-Port Gigabit Ethernet Smart-Lite Switch

 

Содержание GS-7608

Страница 1: ...Lite PoE Switch User Manual GS 7608 8 Port PoE Gigabit Ethernet Smart Lite Switch GS 7605 5 Port PoE Gigabit Ethernet Smart Lite Switch GS 7408 8 Port Gigabit Ethernet Smart Lite Switch GS 7405 5 Port Gigabit Ethernet Smart Lite Switch ...

Страница 2: ...his manual is sold or licensed as is Should the programs prove defective following their purchase the buyer and not Comtrend Corporation its distributors or its dealers assumes the entire cost of all necessary servicing repair and any incidental or consequential damages resulting from any defect in the software Further Comtrend Corporation reserves the right to revise this publication and to make ...

Страница 3: ...3 1 1 Installing Power 11 3 1 2 Connecting to the Network 12 3 1 3 Power over Ethernet PoE Considerations 12 3 2 Starting the Web based Configuration Utility 14 3 2 1 Browser Restrictions 14 3 2 2 Launching the Configuration Utility 14 3 2 3 Logging In 15 3 2 4 Logging Out 15 4 Web based Switch Configuration 16 4 1 System 17 4 1 1 Management 18 4 1 2 Port 19 4 1 3 VLAN 20 4 1 4 Trunking 22 4 1 5 M...

Страница 4: ...Table of Contents ii 4 1 10 IGMP Snooping 30 4 2 PoE 31 4 2 1 Password 33 4 2 2 Logout 33 5 Federal Communication Commission Interference Statement 34 ...

Страница 5: ...uments for which you supply values are in italic Square brackets mean optional elements Braces group required choices and vertical bars separate the alternative elements Braces and vertical bars within square brackets mean a required choice within an optional element Interactive examples use these conventions Nonprinting characters such as passwords or tabs are in angle brackets Notes and cautions...

Страница 6: ...ernet 100Mbps Fast Ethernet and 10Mbps Ethernet network capabilities 1 2 Package contents Before using the product check that the items listed below are included and in good condition If any item does not accord with the table please contact your dealer immediately One of the following Comtrend GS 7608 GS 7605 GS 7408 or GS 7405 AC to DC External PSU with Power Cord GS 7605 only AC Power Cord or E...

Страница 7: ...o GS 7608 1 2 Figure 1 GS 7608 Front View 3 Figure 2 GS 7608 Rear View No Name Description 1 Reset button Press 10 sec to restore factory default parameters 2 Ethernet LAN ports Designed to connect to network devices with a bandwidth of 10Mbps 100Mbps or 1000Mbps Each has a corresponding 10 100 1000Mbps LED PoE on eight ports ports 1 through 8 compatible with IEEE 802 3af with 150W dedicated inter...

Страница 8: ...LED PoE on four ports ports 1 through 4 compatible with IEEE 802 3af with 150W dedicated internal power 3 Power button Press to power on or off the device 4 DC power in Supports 100 240V AC 50 60 Hz The following view applies to GS 7408 1 2 3 Figure 5 GS 7408 Rear View No Name Description 1 Reset button Press 10 sec to restore factory default parameters 2 Ethernet LAN ports Designed to connect to ...

Страница 9: ... devices with a bandwidth of 10Mbps 100Mbps or 1000Mbps Each has a corresponding 10 100 1000Mbps LED 3 DC power in Supports 5V DC 1A 1 4 2 LED Indicators The following view applies to GS 7608 1 2 3 4 Figure 7 GS 7608 LED Indicators No Name Description 1 Power System Off power off On power on system ready Blinking system boot up 2 PoE Max Green LED Off PoE power output under 120W PoE power budget P...

Страница 10: ...ure 8 GS 7605 LED Indicators No Name Description 1 Power System Green LED Off power off or fail On power on Blinking system boot up 2 PoE Max Green LED Off PoE power output under 55W PoE power budget On PoE power output over 55W PoE power budget 3 Port LED LINK ACT bi color LED Off port disconnected or link fail Green on 1000M connected PoE power output on Amber on 10 100M connected Blinking sendi...

Страница 11: ...0M connected PoE power output on Amber on 10 100M connected Blinking sending or receiving data The following view applies to GS 7405 1 2 Figure 10 GS 7405 LED Indicators No Name Description 1 Power Green LED Off power off or fail On power on Blinking system boot up 2 Port LED LINK ACT bi color LED Off port disconnected or link fail Green on 1000M connected PoE power output on Amber on 10 100M conn...

Страница 12: ...To prevent the switch from overheating do not operate it in an area that exceeds an ambient temperature of 122 F 50 C Air Flow Be sure that there is adequate air flow around the switch Mechanical Loading Be sure that the switch is level and stable to avoid any hazardous conditions Circuit Overloading Adding the switch to the power outlet must not overload that circuit 2 2 Desktop Installation To p...

Страница 13: ... the switch to the rack size These extension brackets are mounted on the switch using the screws provided in the kit and have two holes that are used to then screw the switch into the rack An example of one type of these extension brackets is shown in the following figure A common problem that occurs during rack mounting is the distance between the screw holes on the rack Some racks are made with ...

Страница 14: ...Installation 10 2 Secure the switch on the equipment rack with the screws provided Figure 13 Switch on a Rack Installation ...

Страница 15: ...ignated for the switch Disconnect the power cord before installation or cable wiring The Gigabit Ethernet Smart Lite switches are available with different power options from an internal 72W PSU to an external 150W option and power adapters 5V DC 1A It is recommended to connect the switch with a single phase three wire power source with a neutral outlet or a multifunctional computer professional so...

Страница 16: ...ices When you connect your network devices do not exceed the maximum cabling distance of 100 meters 328 feet It can take up to one minute for attached devices or the LAN to be operational after it is connected This is normal behavior Switch ports will automatically adjust to the characteristics MDI MDI X speed duplex of the device to which the switch is connected Figure 15 PC Connect 3 1 3 Power o...

Страница 17: ...bility that PoE switches acting as a PSE may inadvertently detect and supply power an attached PSE including other PoE switches This false detection may result in a PoE switch operating improperly and unable to supply power to attached PDs The prevention of a false detection can be easily remedied by disabling PoE on the ports that are used to connect PSEs Another simple practice to prevent a fals...

Страница 18: ...ad of the IPv6 link local address to access the device from your browser 3 2 2 Launching the Configuration Utility To open the web based configuration utility 1 Open a Web browser 2 Enter the IP address of the device you are configuring in the address bar on the browser the factory default IP address is 192 168 169 1 and then press Enter When the device is using the factory default IP address of 1...

Страница 19: ...login attempt is successful the System Status window displays Figure 17 System Status If you entered an incorrect username or password an error message appears and the Login page remains displayed on the window If you are having problems logging in please see the Launching the Configuration Utility section in the Administration Guide for additional information 3 2 4 Logging Out By default the appl...

Страница 20: ...escribes how to use the web based management interface Web UI to configure the switch s features For the purposes of this manual the user interface is separated into two sections as shown in the following figure 2 1 Figure 18 User Interface No Name Description 1 Configuration menu Navigate to locate specific switch functions 2 Configuration settings Edit specific function settings ...

Страница 21: ...ording to user preference Firmware Version Current firmware version of the device Build Date Device production date MAC Address A unicast MAC address for which the switch has forwarding and or filtering information The format is a six byte MAC address with each byte separated by colons IPv4 Address Switch IPv4 address on the network Subnet Mask A 32 bit number that masks an IP address Loop Status ...

Страница 22: ... Restore switch to original factory default settings Reboot Reboot switch Configuration Restore Backup Path Click to browse a remote TFTP server or on local storage to locate a file with a previously saved switch setting configuration Restore Install selected switch setting configuration file Backup Save current switch setting configuration as a backup file Firmware Upgrade Path Click to browse a ...

Страница 23: ...e Port menu navigate to Port Figure 21 Port Item Description Port Designated port number Link Status Displays whether or not port is in use and link speed if it is in use TX The total number of packets transmitted by the port RX The total number of packets received by the port Loop Status Displays whether or not loops are detected Loop Reset Click to reset loop status Clear Counters Click to reset...

Страница 24: ...ort based VLAN settings Apply Click Apply to save the values and update the screen Port Designated port number PVID Enter a VLAN ID for each port Create New VLAN Click Create New VLAN to enter new VLAN settings VLAN ID Virtual LAN ID Non Member Port is not a member of a VLAN Tag Egress Member Tag outgoing packets of a port which is a member of the VLAN Untag Egress Member Untag outgoing packets of...

Страница 25: ...d VLAN Figure 23 VLAN Port Based VLAN Item Description Add VLAN Click Add VLAN to enter new VLAN settings Apply Click Apply to save the values and update the screen Member Port Click to assign specific ports as members of a VLAN Group ID Identifier of the group of ports in a VLAN Delete Delete a specific VLAN ...

Страница 26: ...ocol LACP To view the Trunking menu navigate to Trunking Figure 24 Trunking Item Description Apply Click Apply to save the values and update the screen LACP Global State Enable disable LCAP Link Aggregation Algorithm Select a link aggregation algorithm MAC SA DA MAC DA MAC SA Link Group Activity Select link group activity status Passive Active Link Group Members The ports that are members of a por...

Страница 27: ...At the time of printing this feature is only available for GS 7405 and GS 7408 To view the Mirror menu navigate to Mirror Figure 25 Mirror Item Description Enable Mirror Enable disable port mirroring Mirror Direction Select the mirror direction Ingress Egress Monitor Port Select the mirror destination port Mirrored Port List The ports or configured to mirror traffic to the destination Multiple sou...

Страница 28: ...ption Disable QoS Enable disable QoS Port Based QoS Click to select port based QoS settings IEEE 802 1p QoS Click to enter IEEE 802 1Q QoS settings Port Based QoS To view the Port Based QoS menu navigate to QoS Port Based QoS Figure 27 QoS Port Based QoS Item Description Disable QoS Enable disable QoS Port Based QoS Click to select port based QoS settings IEEE 802 1p QoS Click to enter IEEE 802 1Q...

Страница 29: ... 1p QoS To view the IEEE 802 1p QoS menu navigate to QoS IEEE 802 1p QoS Figure 28 QoS IEEE 802 1p QoS Item Description Disable QoS Enable disable QoS Port Based QoS Click to select port based QoS settings IEEE 802 1p QoS Click to enter IEEE 802 1Q QoS settings Port Designated port number Weight Queue priority value More packets are sent from a queue with a higher weight value Queue 0 3 Queues use...

Страница 30: ...e for GS 7408 To view the Broadcast Storm Control menu navigate to Broadcast Storm Control Figure 29 Broadcast Storm Control Item Description Broadcast Set Broadcast storm control limit no limit 512K s to 512M s Multicast Set Multicast storm control limit no limit 512K s to 512M s DLF Set DLF storm control limit no limit 512K s to 512M s Apply Click Apply to save the values and update the screen ...

Страница 31: ...7408 Rate Limiting This page displays ingress and egress port limits To view the Rate Limiting menu navigate to Rate Limiting Figure 30 Rate Limiting Item Description Port Designated port number Click individual port numbers to enter rate limit configuration menu for each port Ingress rate The upper limit on how much traffic can enter a port Egress rate The upper limit on how much traffic can exit...

Страница 32: ...ing port number Figure 31 Rate Limiting port number Item Description Apply Click Apply to save the values and update the screen Port Designated port number Ingress rate Select to configure the upper limit on how much traffic can enter a port no limit 512K s to 512M s Egress rate Select to configure the upper limit on how much traffic can exit a port no limit 512K s to 512M s ...

Страница 33: ... time of writing this feature was only available for GS 7608 GS 7408 and GS 7405 To view the Loop Detection Prevention menu navigate to Loop Detection Prevention Figure 32 Network Loop Detection Item Description Off Disable loop detection and prevention Loop Detection Enable loop detection Loop Prevention Enable loop prevention Apply Click Apply to save the values and update the screen ...

Страница 34: ...24 0 0 0 to 239 255 255 255 Based on the IGMP query and report messages the switch forwards traffic only to the ports that request the multicast traffic This prevents the switch from broadcasting the traffic to all ports and possibly affecting network performance To view the IGMP Snooping menu navigate to IGMP Snooping Figure 33 IGMP Snooping Item Description Enable IGMP Snooping Enable disable IG...

Страница 35: ... Settings and PoE Status menu navigate to PoE Figure 34 PoE Menu Item Description PoE Global Settings PSE Total Power Enter values for PSE1 and PSE2 for a total PSE power which must not exceed 130W PoE MAX LED Power Displays the maximum power supplied to LEDs PSE IC Max Temperature Displays upper IC temperature limit which will trigger temperature protection activity PSE IC Real Temperature Displa...

Страница 36: ...dividual port numbers to enter PoE port configuration menu for each port Power Status Displays current port power status on or off Real Power W Displays power drawn by the port in Watts PoE Port Configuration To view the PoE Port Configuration menu navigate to PoE PoE Status and click on an individual port number Figure 35 PoE PoE Status Port Number Item Description Port Designated port number Pow...

Страница 37: ...to Password Figure 36 Password Item Description Confirm Click Confirm to save the values and update the screen Old Password Enter current password New Password Enter new password Confirm New Password Enter new password again to confirm 4 2 2 Logout Click Logout to leave the switch management menu and close the web management session ...

Страница 38: ...t from that to which the receiver is connected 4 Consult the dealer or an experienced radio technician for help Safety This equipment is designed with the utmost care for the safety of those who install and use it However special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment All guidelines of this and of the computer manufactu...

Страница 39: ...Czech Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Latvia Lithuania Luxembourg Malta Netherlands Poland Portugal Romania Slovakia Slovenia Spain Sweden Turkey and United Kingdom The ETSI version of this device is also authorized for use in EFTA member states Iceland Liechtenstein Norway and Switzerland EU Countries Not Intended for Use None Protect Our Environment When the e...

Отзывы: