SLM-5650C / SLM-5650C-ODU Satellite Modem
Revision 1
Serial Remote Control
7–30
MN-SLM-5650C
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Statistics
Sample
Interval
SSI=
1 byte
Command or Query.
Used to set the sample interval for the Statistics Logging Function.
SSI=x, where x = 0 to 9 in 10 minute steps.
Note: Setting this parameter to 0 disables the statistics logging function.
Example: SSI=3 sets the logging inverval to 30 minutes.
SSI=
SSI?
SSI*
SSI#
SSI?
SSI=x
(see Description of Arguments)
Software
Revision
N/A
43 bytes
Query only.
Unit returns the value of the internal software revision installed in the
unit, in the form:
Boot:xx.yy.zz Bulk1:xx.yy.zz Bulk2:xx.yy.zz
Example: SWR=Boot:01.01.01 Bulk1:01.01.01 Bulk2:01.01.01
N/A
SWR?
SWR=Boot:xx.yy.zz Bulk1:xx.yy.zz
Bulk2:xx.yy.zz
(see Description
of Arguments)
RTC Time
TIM=
6 bytes
Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
TIM=
TIM?
TIM*
TIM#
TIM?
TIM=hhmmss
(see Description of Arguments)
Temperature N/A
3 bytes
Query only.
Unit returns the value of the internal temperature, in the form of xxx
(degrees C).
Example: TMP=+26
N/A
TMP?
TMP=xxx
(see Description of Arguments)
AGC Monitor
Min Voltage
AGN=
3 bytes
Command or Query.
Used to set the AGC Monitor Min Voltage to x.x (0 to 5 Volts), i.e. -60
dBm
Example: AGN=1.0
AGN=
AGN?
AGN*
AGN#
AGN?
AGN=x.x
(see Description of Arguments)
AGC Monitor
Max Voltage
AGX=
3 bytes
Command or Query.
Used to set the AGC Monitor Max Voltage to x.x (0 to 5 Volts), i.e. +15
dBm
Example: AGX=5.0
AGX=
AGX?
AGX*
AGX#
AGX?
AGX=x.x
(see Description of Arguments)
Modem IP
Interface
Security
Mode
MIS=
1 byte
Command or Query.
Used to set the modem IP Interface security level where:
0 = Normal or Low Level Security (SNMP v1/v2c)
1 = High Level Security (SNMP v3)
Example: MIS=0
MIS=
MIS?
MIS*
MIS#
MIS?
MIS=x
(see Description of Arguments)
Содержание SLM-5650C CyberLynx
Страница 12: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Table of Contents TOC 10 BLANK PAGE ...
Страница 36: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Introduction 1 18 MN SLM 5650C BLANK PAGE ...
Страница 40: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Installation 2 4 MN SLM 5650C BLANK PAGE ...
Страница 104: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Serial Remote Control 7 10 MN SLM 5650C BLANK PAGE ...
Страница 146: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix A A 12 MN SLM 5650C BLANK PAGE ...
Страница 162: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix B B 16 MN SLM 5650C BLANK PAGE ...
Страница 167: ......
Страница 168: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...