background image

 

Part Number MN-RCS11

 

 

Revision 9

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 

 
 

 
 

 

 

 
 

 

 

IMPORTANT NOTE: The information contained in this document supersedes all previously 
published information regarding this product. This manual is subject to change without prior notice. 

RCS11 

1:1 Redundancy Switch 

Installation and Operation Manual

 

Содержание Radyne RCS11

Страница 1: ...ANT NOTE The information contained in this document supersedes all previously published information regarding this product This manual is subject to change without prior notice RCS11 1 1 Redundancy Sw...

Страница 2: ......

Страница 3: ...Alarm Fault Cable name Date July 9 2010 Original Manual Part Number MN RCS11 Rev 9 Errata Number Agile Document ID ER RCS11 EA9 Agile CO Number C12397 Change Specifics This information will be incorpo...

Страница 4: ...3 HSSI Interfaces Table 4 3 describes the connection hardware required RX IN TX OUT 1 2 2 2 2 3 3 4 DATA IN OUT Figure 4 3 RCS11 with HSSI G 703 Interface Connected to DMD20 DMD50 or DMD2050 Modems wi...

Страница 5: ...DMD50 Modems with 70 140 MHz option utilizing the ASI DVB data Interfaces Table 4 4 describes the connection hardware required Figure 4 4 RCS11 with HSSI ASI Interface Connected to DMD20 DMD50 or DMD...

Страница 6: ...odems with HSSI Interfaces Table 4 5 describes the connection hardware required Figure 4 5 RCS11 with HSSI ASI Interface Connected to DMD20 Modems with HSSI Interfaces Table 4 5 Connection Hardware It...

Страница 7: ...ights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161 RCS11 1 1 Redundancy Switch Installation and Operation Manual Part Number M...

Страница 8: ...This page is intentionally blank...

Страница 9: ...to Figure 2 1 2 2 2 2 3 Manual Mode 2 2 2 2 4 Auto Mode 2 2 2 2 5 Power Up Defaults 2 2 2 3 RCS11 Major Assemblies 2 2 2 3 1 Main Switch Board 2 3 2 3 2 Front Panel Board 2 3 2 3 3 Redundant Power Su...

Страница 10: ...iversal 4 4 4 6 2 DMD20 or DMD50 Universal with G 703 IBS IDR Interface 4 5 4 6 3 DMD20 or DMD50 with HSSI Interface 4 6 4 6 4 DMD20 or DMD50 ASI DVB with RCS11 ASI HSSI 4 7 4 6 5 DMD20 HSSI 4 8 4 6 6...

Страница 11: ...J7 5 9 5 6 2 ASI TERR J10 5 9 5 6 3 DATA B J11 5 9 5 6 4 Alarm A J18 5 9 5 6 5 Alarm B J19 5 10 5 7 DVB Parallel Interfaces 5 10 5 7 1 Data A Data B DVB Parallel Interface J7 5 10 5 7 1 1 Data A Data...

Страница 12: ...30 J10 5 22 5 10 2 Ethernet Interface 5 23 5 10 2 1 DATA B J27 5 23 5 10 2 2 TERR DATA J28 5 23 5 10 2 3 DATA A J29 5 23 5 10 2 4 SWITCH S1 5 23 5 11 SERIAL INTERFACE 5 23 5 11 1 TERRESTRIAL RS449 RS4...

Страница 13: ...H CONFIGURATION A 1 APPENDIX B RCS11 REMOTE COMMUNICATIONS B 1 B 1 Host Computer Remote Communications B 1 B 1 1 Protocol Structure B 1 B 1 2 Protocol Wrapper B 2 B 1 3 Frame Description and Bus Hands...

Страница 14: ...RCS11 1 1 Redundancy SwitchTable of Contents Revision 9 Table of Contents MN RCS11 viii Notes...

Страница 15: ...content and design of this manual are appreciated To submit comments please contact the Comtech EF Data Technical Publications department TechnicalPublications comtechefdata com Conventions and Refere...

Страница 16: ...dicates a statement associated with the task being performed or information critical for proper equipment function CAUTION CAUTION indicates a hazardous situation that if not avoided may result in min...

Страница 17: ...ation as defined in EN60950 Low Voltage Directive LVD The following information is applicable for the European Low Voltage Directive EN60950 HAR Type of power cord required for use in the European Com...

Страница 18: ...ech EF Data Corporation s obligations under this warranty are limited to repair or replacement of failed parts and the return shipment to the buyer of the repaired or replaced parts Limitations of War...

Страница 19: ...tated is in lieu of all other warranties expressed implied or statutory including those of merchantability and fitness for a particular purpose The buyer shall pass on to any purchaser lessee or other...

Страница 20: ...er serial number and a description of the problem Request a Return Material Authorization RMA number from the Comtech EF Data Customer Support representative Pack the product in its original shipping...

Страница 21: ...only applications Operating in the Automatic Mode the RCS11 immediately places a Backup Modem online in the event of a Primary Online Modem failure In the Manual Mode the user may designate the selec...

Страница 22: ...onfiguration into nonvolatile memory If the power source was then to fail and be restored the RCS11 would again power up in the Auto Mode with both the Modulator and Demodulator set to Modem B Univers...

Страница 23: ...CS11 Revision 9 1 3 Optional HSSI and G703 or ASI Interface used with DM240XR DD240XR DMD20 DMD50 Optional Ethernet Interface used with DM240XR DD240XR DMD20 50 Optional T3 E3 Interface used with DMD5...

Страница 24: ...RCS11 1 1 Redundancy Switch Introduction MN RCS11 Revision 9 1 4 Figure 1 3 RCS11 Functional Block Diagram...

Страница 25: ...require minimal operator intervention and control during normal operation After initial setup the unit should operate in a relatively transparent manner providing trouble free backup of the online Mo...

Страница 26: ...ult signals until placed back into Auto Mode 2 2 4 Auto Mode To enable automatic backup in the event of a MOD or DEMOD failure the RCS11 must be placed into the Auto Mode First select which MOD and DE...

Страница 27: ...The 1 1 Switch comes equipped with two fully redundant internal power supplies PS1 and PS2 that supplies power to the system Each supply is fully independent of the other including their source of AC...

Страница 28: ...ay switches to a faulted state If Power Supply 1 and Power Supply 2 simultaneously fail the switching circuitry in the RCS11 reverts back to Modem A and the Switch Fault Relay switches to a faulted st...

Страница 29: ...n for Power Available Fault Indicates a Switch Fault has occurred LED illuminates Red for Switch Fault Auto LED Indicates RCS11 is in the Auto Mode LED illuminates Green for Auto Mode Manual LED Indic...

Страница 30: ...eived a fault from Modulator A or B LED illuminates Red for Fault SELECT Mod A or B Pushbutton Allows the operator to select a Modulator A or B 3 3 Rear Panel Interface 3 3 1 System Installation and C...

Страница 31: ...J1 FAULT 9 Pin F D Sub Switch Fault Status J2 REMOTE 9 Pin F D Sub 232 or 485 Communications J3 TX B BNC IF Transmit Input From Primary Device J4 TX Out BNC Main IF Output J5 TX A BNC IF Transmit Inp...

Страница 32: ...Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 DATA A BNC Asynchronous Data from Primary Device J10 ASI TERR BNC Asynchronous Data Out J11 DATA B BNC Asynchronous Data from Back Up Device J18 A...

Страница 33: ...ction hardware required Figure 3 3 RCS11 DVB Parallel Interface RS422 and LVDS Table 3 3 Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 DATA A 25 Pin F D Sub Parallel RS422 and LVDS Data A J10...

Страница 34: ...Interface can be configured from the factory to support ASI Asynchronous Serial Interface Figure 3 4 RCS11 HSSI G 703 Interface Table 3 4 Connection Hardware LOCATION CONNECTOR DESCRIPTION J8 TERR DA...

Страница 35: ...100 1000 N O T E O n t h e S 1 Switch moving the switch to the left sets the unit to the Modem Feature moving the switch to the right sets the unit to the Mod Demod Feature NOTE Power must be cycled...

Страница 36: ...kup Device J15 ESC 8K Data 15 Pin D Sub Female Eng Service Channel for Teletype J16 ESC Voice 9 Pin D Sub Female Eng Service Channel for Voice or 64k Data J17 ESC Alarms 25 Pin D Sub Female Eng Servic...

Страница 37: ...onnection hardware required Figure 3 8 RCS11 RS449 422 Serial Interface Table 3 7 Connection Hardware LOCATION CONNECTOR DESCRIPTION J7 Data A 37 Pin D Sub Data Primary Device J10 Terrestrial Data 37...

Страница 38: ...RCS11 1 1 Redundancy Switch User Interfaces MN RCS11 Revision 9 3 10 Notes...

Страница 39: ...NG There are no user serviceable parts or configuration settings located inside the RCS11 Chassis There is a potential shock hazard internally at the power supply module DO NOT open the RCS11 Chassis...

Страница 40: ...preparation simplifies the installation process and results in a more reliable system The user should ensure that the site has adequate electrical power environmental controls and protection against s...

Страница 41: ...intenance and Troubleshooting 4 5 System Connections For initial RCS11 setup and configuration perform the following procedure 1 Verify that the AC Power Cords to the RCS11 and units to be connected a...

Страница 42: ...earth protection In addition the IF input and output coax cable shielding must be properly terminated to the Chassis unit ground 4 6 Connections This section provides data and frequency connections i...

Страница 43: ...1 system using the RCS11 with the Universal Interface connected to DMD20 Modems with 70 140 MHz IF configuration and G 703 IBS IDR Interfaces Table 4 2 describes the connection hardware required RX I...

Страница 44: ...HSSI Interfaces Table 4 3 describes the connection hardware required RX IN TX OUT 1 2 2 2 2 3 3 4 DATA IN OUT Figure 4 3 RCS11 with HSSI G 703 Interface Connected to DMD20 DMD50 or DMD2050 Modems wit...

Страница 45: ...DMD50 Modems with 70 140 MHz option utilizing the ASI DVB data Interfaces Table 4 4 describes the connection hardware required Figure 4 4 RCS11 with HSSI ASI Interface Connected to DMD20 DMD50 or DMD...

Страница 46: ...dems with HSSI Interfaces Table 4 5 describes the connection hardware required Figure 4 5 RCS11 with HSSI ASI Interface Connected to DMD20 Modems with HSSI Interfaces Table 4 5 Connection Hardware Ite...

Страница 47: ...140 MHz and Ethernet Data Interfaces Table 4 6 describes the connection hardware required RX IN DATA IN OUT TX OUT 1 2 2 2 2 3 3 4 4 Figure 4 6 RCS11 with Ethernet Interface Connected to DMD20 Modems...

Страница 48: ...D50 or DMD2050 Modems with 70 140 MHz and T3 E3 Interface Table 4 7 describes the connection hardware required Figure 4 7 RCS11 with a E3 T3 STS1 Interface Connected to a DMD50 or DMD2050 Modems with...

Страница 49: ...IC Modulators with 70 140 MHz and ASI PIIC Card Table 4 8 describes the connection hardware required Figure 4 8 RCS11 with ASI Interface Connected to DM240 PIIC Modulators with an ASI PIIC Card Table...

Страница 50: ...ptional Offline IF Monitor connected to DM240XR Modulators Table 4 9 describes the connection hardware required ASI IN TX OUT 1 2 2 1 1 1 Figure 4 9 RCS11 with ASI Interface and optional Offline IF Mo...

Страница 51: ...Demodulators Table 4 10 describes the connection hardware required RX IN 1 2 3 2 3 4 4 DATA OUT Figure 4 10 RCS11 with Ethernet Interface Connected to DD240XR Demodulators Table 4 10 Connection Hardwa...

Страница 52: ...t Interface connected to DM240XR Demodulators Table 4 11 describes the connection hardware required Figure 4 11 RCS11 with Ethernet Interface Connected to DM240XR Modulators Table 4 11 Connection Hard...

Страница 53: ...modulators with HSSI PIIC Cards Table 4 12 describes the connection hardware required DATA IN TX OUT 1 2 3 1 2 Figure 4 12 RCS11 with HSSI ASI Interface Connected to DM240XR Modulators with HSSI PIIC...

Страница 54: ...with DVB M2P Parallel PIIC Cards Table 4 13 describes the connection hardware required DATA IN TX OUT 1 1 2 2 3 3 Figure 4 13 RCS11 with Parallel Interface Connected to DM240XR Modulators With DVB Pa...

Страница 55: ...140 MHz IF and HSSI Data Interfaces Table 4 14 describes the connection hardware required Figure 4 14 RCS11 with HSSI ASI Interface connected to DD240XR Demodulators with HSSI Interface Table 4 14 Co...

Страница 56: ...ilizing the HSSI Interfaces Table 4 15 describes the connection hardware required Figure 4 15 RCS11 with HSSI ASI Interface Connected to DM240XR Modulators and DD240XR Demodulators with HSSI Interface...

Страница 57: ...49 Serial Interface connected to DMD20 s using the EIA 530 connection Table 4 16 describes the connection hardware required Figure 4 16 RCS11 with Serial Interface Connected to DMD20 s Table 4 16 Conn...

Страница 58: ...S11 will not pass BUC Voltage Table 4 17 describes the connection hardware required Figure 4 17 RCS11 with Serial Interface Connected to DMD20LBST s Table 4 17 Connection Hardware Item No Quantity Par...

Страница 59: ...supplied power cables is 10 240 VAC 50 60 Hz Integrated into each of the power entry module is the Power On Off Rocker Switch Power consumption for the unit is 1A The Power Cord Connector assembly is...

Страница 60: ...Mod B Selected Relay Normally Closed 4 Demod B Selected Relay Common 5 Demod B Selected Relay Normally Open 6 Switch Fault Relay Normally Closed 7 Mod B Selected Relay Common 8 Mod B Selected Relay No...

Страница 61: ...TX IF input from the modulator If the RCS11 is configured for a 70 or 140 MHz application then this connector is either a 75 Ohm or 50 Ohm BNC connector If the switch is configured for L Band then thi...

Страница 62: ...Input 5 5 2 MODEM A B J7 J11 G703 RS422 Serial Universal Interface w SCSI connectors The Modem Channel a Port is a 68 Pin High Density Female SCSI Connector This port is the data interface used to co...

Страница 63: ...Output 26 IDR ESC Receive 8 Kbps Clock Input 27 IDR ESC Receive 8 Kbps Data Input 28 IDR ESC Backward Alarm Output 4 Normally Closed 29 IBS Transmit Octet A Output 30 Synch Data Data Mode A Input 31...

Страница 64: ...IDR ESC Backward Alarm 4 Normally Open 63 IBS Transmit Octet B Output 64 Synch Data Data Mode B Input 65 Synch Data Clear to Send B Output 66 IBS Receive Octet B Input 67 Synchronous Data Request to...

Страница 65: ...or Refer to Table 5 7 for pinouts Table 5 7 J17 ESC ALARMS 25 Pin Female D Pin Description Signal 1 7 Ground GND 2 Backward Alarm Out 1 Normally Open 3 5 9 12 13 24 25 Not Used NA 4 Backward Alarm Out...

Страница 66: ...ed Together 3 TXD A Transmit Data A 8 CTS Clear to Send 4 TXD B Transmit Data B 9 NC No Connection 5 GROUND Signal Ground 5 5 7 G 703 Balanced J20 The G 703 Port is a Balanced 15 Pin Female D Connecto...

Страница 67: ...ASI serial data for the DM240XR Modulator or DD240XR Demodulator only application 5 6 1 DATA A J7 The Data A is the serial ASI data interface from the modulator or demodulator A This interface is a 7...

Страница 68: ...P Parallel RS422 or LVDS protocols The modulators or Demodulators must be configured to support RS422 or LVDS protocol 5 7 1 Data A Data B DVB Parallel Interface J7 The Data A and Data B DVB Parallel...

Страница 69: ...interface connects to A or B Modulator or Demodulator Refer to Table 5 13 for pinouts Table 5 13 J7 Data A M2P Parallel 25 Pin Female D Pin No Description Signal 1 OUTCLK Input 14 OUTCLK Input 2 CLK O...

Страница 70: ...for pinouts Table 5 14 J10 Terrestrial Data DVB Parallel 25 Pin Female D Pin Description Signal 1 Clock Input 2 15 System Ground GND 3 D7 Input 4 D6 Input 5 D5 Input 6 D4 Input 7 D3 Input 8 D2 Input...

Страница 71: ...r pinouts Table 5 15 J10 Terrestrial Data M2P Parallel 25 Pin Female D Pin No Description Signal 1 OUTCLK Output 14 OUTCLK Output 2 CLK Input 15 CLK Input 3 SYNC Input 16 SYNC Input 4 VALID Input 17 V...

Страница 72: ...round GND 6 Mod Fault Open Collector Input 5 8 DMD50 UNIVERSAL G703 T3 E3 RS422 SERIAL INTERFACE w SCSI The RCS11 Unversal G703 Unbalanced Synchrounous Interface supports RS422 Serial data and G703 T3...

Страница 73: ...supplies the Synchrounous G703 IDR and IBS data information from the modems Refer to Table 5 19 for pinouts Table 5 19 J7 J11 MODEM A 68 Pin Female High Density Connector Pin No Description Signal 1...

Страница 74: ...eiver Ready A Input 35 G 703 Send Data B Output 36 Synch Data Send Data Input B Output 37 IDR ESC Backward Alarm 1 Normally Closed 38 G 703 Insert Data Input B Output 39 Synch Data Send Timing B Input...

Страница 75: ...A J15 The ESC 8K Data Port is a 15 Pin Female D Connector Refer to Table 5 20 for pinouts Table 5 20 ESC 8K Data Interface 15 Pin Female D Connector J15 Pin No Description Signal 1 Rx Octet B Output 2...

Страница 76: ...d GND 2 Backward Alarm Out 1 Normally Open 3 5 9 12 13 24 25 Not Used NA 4 Backward Alarm Out 2 Normally Open 6 Backward Alarm Out 3 Normally Open 8 Backward Alarm Out 4 Normally Open 10 Backward Alar...

Страница 77: ...CTS Clear to Send 4 TXD B Transmit Data B 9 NC No Connection 5 GROUND Signal Ground 5 8 7 RXB J30 Modem B RX Data Port SD is a G703 Unbalanced 75 Ohm Female BNC Connector 5 8 8 TERR RX J31 The TERR R...

Страница 78: ...ace 50 Pin Connector Pin No Pin No Signal Name Description Direction 1 26 SG Signal Ground 2 27 RT Receive Timing Output 3 28 CA DCE Available Output 4 29 RD Receive Data Output 6 31 ST Send Timing SC...

Страница 79: ...or G703 interface 5 9 2 6 RXB ASI or G 703 J20 Modem B RX Data Port SD is an ASI or G703 Unbalanced 75 Ohm Female BNC Connector RCS11 Switch must be ordered supporting either ASI or G703 interface 5 9...

Страница 80: ...le 5 26 J36 EIA 530 25 Pin Female D Pin No Signal Name Direction 1 Shield GND 2 Send Data A Input 3 Receive Data A Output 4 Request To Send A Input 5 Clear To Send A Output 6 Data Mode A Output 7 Sign...

Страница 81: ...e can be configured to support a modem or Modulator Demodulator The S1 switch must be properly set to the correct position to support the modem or Modulator Demodulator NOTE On the S1 Switch moving th...

Страница 82: ...A Input 5 Send Timing A Output 6 Receive Data A Output 7 Request To Send A Input 8 Receive Timing A Output 9 Cllear To Send A Output 11 Data Mode A Output 13 Receive Ready A Output 15 External Clock A...

Страница 83: ...O Buffer Output Clock A Output 4 Transmit Data A Output 5 Transmit Clock A Input 6 Receive Data A Input 7 RTS A Output 8 Receive Clock A Input 9 CTS A Input 11 Data Mode A Input 12 DTR A Output 13 Rec...

Страница 84: ...RCS11 1 1 Redundancy Switch Connector Pinouts MN RCS11 Revision 9 5 26 Notes...

Страница 85: ...Comtech EF Data Customer Service Department at 480 333 4357 for further information and instructions 6 2 Basic User Checks Upon the detection of an operational failure the source of the failure must...

Страница 86: ...oose connections Cables that are suspect should be replaced All jacks on the units have no bent or broken pins Both AC Power Cords are properly plugged into the rear of the RCS11 6 3 Major and Minor F...

Страница 87: ...rating parameters can be monitored and controlled via the front panel display keypad or the RS 485 or RS 232 serial control channel in either terminal or command modes The following modem parameters m...

Страница 88: ...rsal G703 T3 E3 STS1 HSSI Universal ASI Ethernet 10 100 Base T RS530 7 5 Front Panel LED Indicators Unit Power Supply 1 Power Supply 2 Switch Fault Auto Manual Demodulator Online A B Fault A B Modulat...

Страница 89: ...change from an existing interface or configuration to another may require a change to one or more of the DIP switch settings If you are having trouble with DIP switch settings contact Radyne Customer...

Страница 90: ...e Port J 20 with the switch in Terminal Mode An empty space in Table A 1 represents the off position Table A 1 Baud Rate Switch Positions BAUD RATE SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8 9600 4800 ON...

Страница 91: ...d 82 ON ON ON 83 ON ON ON ON 84 ON ON ON 85 ON ON ON ON 86 ON ON ON ON 87 ON ON ON ON ON 88 ON ON ON 89 ON ON ON ON 90 ON ON ON ON 91 ON ON ON ON ON 92 ON ON ON ON 93 ON ON ON ON ON 94 ON ON ON ON ON...

Страница 92: ...tes how to configure the Dip Switches for RS232 Data on an RCS11 with Universal Data Interface Figure A 3 DIP Switch on the RS232 Driver Figure A 4 Illustrates how to configure the Dip Switches for G...

Страница 93: ...ions MN RCS11 Revision 9 A 5 Figure A 5 Illustrates standard jumper blocks for fault execution on all Radyne products J4 and JP1 Shunt Blocks should be installed as a factory default configuration J4...

Страница 94: ...RCS11 1 1 Redundancy Switch RCS11 DIP Switch Configurations MN RCS11 Revision 9 A 6 Notes...

Страница 95: ...ender changes port from RS232 to RS485 B 1 1 Protocol Structure The Communications Specification COMMSPEC defines the interaction of computer resident Monitor and Control software used in satellite ea...

Страница 96: ...beginning of a message The SYN character value is always 16h DATA COUNT the 2 Byte Data Count is the number of bytes in the DATA field ranging from 0 through 509 SOURCE ID the Source Identifier define...

Страница 97: ...e entire message frame is discarded and the wait for SYN mode goes back into effect If the OPCODE resides within a command message it defines the class of action that denotes an instruction which is s...

Страница 98: ...devices slaved to an M C computer the timeout delay parameters may be programmed into the equipment in accordance with site requirements by Radyne Corp prior to shipment or altered by qualified person...

Страница 99: ...a to form information packets Each transmitted packet is subject to time out and frame sequence control parameters after which the packet sender waits for the receiver to convey its response Once a re...

Страница 100: ...1 byte BYTE COUNT Number of bytes in the DATA field 2 bytes SOURCE ID Identifies the address of the equipment from where the message originated 1 byte DEST ID Identifies the address of the equipment...

Страница 101: ...Device Firmware Version LSB binary number implied decimal point 10 Device Firmware Name null terminated string 7 Device Firmware Release Date null terminated string Opcode 2280h Command RCS11 Load Fa...

Страница 102: ...Field 8 Bytes 1 Switch Delay Mod Fault MSB 1 Switch Delay Mod Fault LSB 1 Switch Delay Mod NoFault MSB 1 Switch Delay Mod NoFault LSB 1 Switch Delay Demod Fault MSB 1 Switch Delay Demod Fault LSB 1 Sw...

Страница 103: ...mware Error Enabled Bit 3 1 Switch NV Alarm Bit 4 1 Switch Internal Alarm Enabled Bit 5 7 unused return 0 2 Spare Current Alarms Always 0 Opcode 2289h Command RCS11 Switch Alarms Masks Command Data Fi...

Страница 104: ...RCS11 1 1 Redundancy Switch RCS11 Remote Communications MN RCS11 Revision 9 B 10 Notes...

Страница 105: ...n power up you should receive the following text RCS11 1 1 Redundancy Switch Copyright c 1996 1997 Radyne At the terminal screen you will receive a prompt _ Typing help and pressing Enter will cause t...

Страница 106: ...thout additional parameters or miss spelling of the command will return an error message baud Error BAD ARGUMENT staus Error BAD COMMAND Queries Help Status and Ver are typed without addition paramete...

Страница 107: ...of ticks that will occur before the RCS11 considers a demod as not faulted If a demod faults and recovers before the demod fault delay then the RCS11 will start counting for the demod non fault delay...

Страница 108: ...RCS11 1 1 Redundancy Switch Terminal Communications MN RCS11 Revision 9 C 4 Notes...

Страница 109: ...3 1 760 x 103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoirdupois Pound Troy Kilogram 1 gram 0 03527 0 032...

Страница 110: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...