Hardware Installation
Memotec Inc.
3-25
3.9.1
E&M Grounding Considerations
Proper grounding is essential for correct operation of telephone equipment in E&M
applications. E&M signaling works by applying DC voltages to the E and M leads for
connecting and disconnecting. Without a proper ground, the DC voltages do not have a
common point of reference, which can result in unintended or sporadic signaling.
Distance may be an important factor for an E&M interface on the SDM-9220 UAC and
SDM-9230 UAC. If the PBX and the NetPerformer UAC unit are not near each other (in
the same room, for example) then their AC grounds may not be the same. To avoid
grounding problems on the UAC unit, ensure that your installation respects the following
conditions:
•
Check the distance between the PBX and the NetPerformer UAC unit.
-
If the two are not within close proximity, then their AC grounds may not be
the same.
-
If the NetPerformer UAC unit and the PBX are in the same room, it is likely
that they share the same AC ground.
•
In an E&M application, the common ground must be the Telco/PTT ground. This
ensures that the ground potential of the PBX telephone interface and the
NetPerformer telephone interface are the same.
Based on the above conditions, grounding may be established directly or indirectly.
•
Direct Method
:
Connect a grounding wire between the Telco/PTT interfaces on
the PBX and the NetPerformer UAC unit.
-
Connect the ground wire from the PBX to pin 8 (SG) of the RJ45 connector
on the E&M interface card.
This will establish the same ground potential at both interfaces.
•
Indirect Method
:
If direct grounding is not possible or practical, establish an
indirect ground.
-
Make sure the Telco/PTT grounds of the PBX and the NetPerformer UAC
unit are connected to their respective AC grounds.
Check with the PBX manufacturer for information on how to connect the
PBX AC ground to the Telco/PTT ground.
-
The AC grounds of the two devices must be at the same potential, which is
usually the case when they are located in close proximity.
CAUTION:
:
Connecting the AC ground to the Telco/PTT ground on telephone
equipment may violate the rules of certain regulatory agencies. For complete
grounding regulations, please check with your local telephone company and/or
agency.
Содержание NetPerformer SDM-9 Series
Страница 1: ...NetPerformer SDM 9120 9220 9230 Series Hardware Installation Guide ...
Страница 10: ...Memotec Inc ...
Страница 11: ...Memotec Inc 1 1 1 Preface ...
Страница 21: ...2 Memotec Inc 2 1 Unpacking ...
Страница 27: ...3 Memotec Inc 3 1 Hardware Installation ...
Страница 62: ...SDM 9XXX Series Hardware Installation Guide 3 36 Memotec Inc ...
Страница 63: ...4 Memotec Inc 4 1 Product Description ...
Страница 99: ...5 Memotec Inc 5 1 Serial Port and User Equipment Connections ...
Страница 108: ...SDM 9XXX Series Hardware Installation Guide 5 10 Memotec Inc ...
Страница 109: ...6 Memotec Inc 6 1 Troubleshooting Tips ...
Страница 113: ...A Memotec Inc A 1 Appendix A Warranty Information This appendix explains the conditions of the product warranty ...
Страница 117: ...B Memotec Inc B 1 Appendix B Compliance Information and Safety Warning ...
Страница 121: ...Memotec Inc B 5 ...
Страница 128: ...SDM 9XXX Series Hardware Installation Guide B 12 Memotec Inc ...
Страница 133: ...Memotec Inc B 17 Compliance to China RoHS ...
Страница 135: ...Memotec Inc B 19 ...