Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–13
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Attenuation
ATT=
ATT?
5 bytes
Command or Query.
Sets or returns the attenuation level in the form xx.xx, where:
xx.xx=00.00 to 20.00, in dB, in 0.25 dB steps
Default value: 10.00
COMMAND EXAMPLE: <0001/ATT=12.25{CR}
ATT=
ATT?
ATT*
ATT=xx.xx
Auxiliary Mute
Enable
AUX=
AUX?
1 byte
Command or Query.
Sets or returns the auxiliary mute mode in the form x, where:
0=Disabled (DEFAULT)
1=Enabled
NOTES:
1)
When enabled, the mute control input on the remote com connector must be
grounded to UN-MUTE the unit. Otherwise, the unit will be muted, and if a
mute query is given (MUT?) the response will be MUT=2 to indicate a
hardware controlled mute is present.
2)
Aux mute is one of several hardware mute states that can cause a MUT=2 to
be reported. See the MUT command for more info on mute states.
3)
Aux mute supersedes the user mute state so if the command MUT=1 is sent,
then AUX=1 is sent, and the user shorts Pin K to Pin S on the discrete control
connector; the RF mute will then be disabled (MUT=0).
COMMAND EXAMPLE: <0001/AUX=1{CR} (enables Aux Mute)
AUX=
AUX?
AUX*
AUX=x
Clear All Stored
Alarms*
CAA=
N/A
None
Command only.
Instructs the LPOD to Clear All stored Alarms. This command takes no
arguments.
EXAMPLE: <0001/CAA={CR}
CAA=
CAA*
N/A
Clear All Stored
Events
CAE=
N/A
None
Command only.
Instructs the LPOD to Clear All stored Events. This command takes no
arguments.
EXAMPLE: <0001/CAE={CR}
CAE=
CAE*
N/A
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...