LGaN
Revision 0
Ethernet Interface Operation
4–9
MN-LGAN
Figure 4-5. Telnet Login and Remote Command Execution
You must assign a unique IP Address (IPA) for each unit on the network before
connecting to an existing network. As the IP address may need to be changed to
something other than the factory default setting, use the remote command
IPA=xxx.xxx.xxx.xxx.yy, where: xxx.xxx.xxx.xxx is a valid IP address on the network
where the unit is to be installed, and yy is the range (typically, yy = 24).
Changing the IPA value requires that you cycle power on the unit, and then start a new
Telnet session using the new IP address.
4.4.2 HTTP Interface User Login
Do these steps:
1. From the PC, enter the default Management IP Address for the LGaN (i.e.,
http://192.168.1.4
) into
the
Address
area of the browser.
2. In the Login window, type the
User name
and
Password
, and then click
OK
. The default User
Name and Password are both
comtech
.