LBC-4000 L-Band Up/Down Converter System
Revision 6
Front Panel Operation
6–16
MN-LBC-4000
These screens show the active Conv-A and Conv-B for the LBC-4000 and only Conv-A for the
LBC-4000-ST Up and/or Down Converter IDU operating parameters fault states, where:
•
iflo
= IF Lockout Fault
•
rflo
= RF Lockout Fault
•
temp
= Operating Temp Fault (°C)
Faults: Power Supply A
▲
12VT=OK 08V=OK 05V=OK
▼
Faults: Power Supply B
▲
12VT=OK 08V=OK 05V=OK
▼
These screens show the active
PS A
and
PS B
(power supply) 12 V, 8 V, and 5 V fault states.
Faults: Ext Ref
▲
Ext Ref = FT
▼
This screen displays the external reference oscillator fault state.
Press
[ENT]
or
[CLR]
to continue.
6.3.5.2
(FAULTS:) STORED
VIEW CLEAR-ALL
Use the
[
][
]
arrow keys to select
VIEW
or
CLEAR-ALL
. Press
[ENT]
.
6.3.5.2.1
(FAULTS:) STORED
VIEW
If you select
View
and no faults exist in the stored faults log, the system displays this message:
No Stored Faults
.
Otherwise, stored faults log entries display as per this example:
Fault No. 06 10:28:53
▲
OK-IFLO_A 08/10/16
▼
Use the
[
][
]
arrow keys to page between screens. The faults log can store up to
100
faults.
When a fault condition occurs, the unit assigns a number to the fault (in the order received), date-
and time-stamps the fault, and provides a condensed description of the issue. When the fault
condition clears, this action is recorded in the same fashion as the fault was originally recorded.
Содержание LBC-4000
Страница 36: ...LBC 4000 L Band Up Down Converter System Revision 6 Installation and Startup 3 8 MN LBC 4000 BLANK PAGE...
Страница 64: ...LBC 4000 L Band Up Down Converter System Revision 6 Firmware Update 5 16 MN LBC 4000 BLANK PAGE...
Страница 134: ...LBC 4000 L Band Up Down Converter System Revision 6 Serial Interface Operation 8 24 MN LBC 4000 BLANK PAGE...
Страница 140: ...LBC 4000 L Band Up Down Converter System Revision 6 Appendix A A 6 MN LBC 4000 Notes...
Страница 147: ......
Страница 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...